0 = hand-off function off, Back-EMF off
1 = hand-off function on, Back-EMF off
2 = hand-off function off, Back-EMF on
3 = hand-off function on, Back-EMF on Hand-off function on:
When operating with 55015, you can adjust direction and
speed for two seconds after selecting a moving loco without
causing the loco to stop.
CV55
Reset of most programmed CVs
55 = most important CVs are reset to the factory pre-set values
CV60
Back-EMF: Max. adjustment factor (0: small, 255: large)
Specifies the max. increase or decrease of voltage applied
during each time interval (programmed in CV61)
Attention! The factory pre-set values of CV60 and CV61 are
optimized for LGB motors.
CV61
Back-EMF: Adjustment frequency (0: often, 255: seldom)
Specifies how often per second the motor voltage is adjusted -
accordingly, the loco will react to curves and grades immediately
or with a short delay
CV62
Back-EMF: Max. Adjustment (0: small, 255: max.)
Limits the total adjustment in motor voltage. If there is a very
large load on the motor, the adjustment will not exceed this
value - for more realistic operations, so that locos will slow a
bit on grades.
CV67
Speed steps programmed by user (see CV29):
to
28 speed steps are programmed in CV67 to CV94.
CV94
With LGB MTS, every second value is skipped (14 speed steps).
Factory pre-set speed steps:
7, 9, 11, 13, 16, 20, 24, 28, 32, 36, 42, 48, 54, 60, 68, 76, 84,
92, 102, 112, 124, 136, 152, 168, 188, 208, 230, 255
Pre-set values for user-programmable speed steps:
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96, 104, 112, 120, 128,
136, 144, 152, 160, 168, 176, 184, 192, 208, 224, 240, 255
Hint: The speed steps are factory pre-set and programming is
not necessary. Use the 55045 MTS PC Decoder Programming
Module for programming.
14
General programming
procedure with 55015 Universal
Remote:
- Registers CV1 through CV4 can be
programmed directly by program-
ming the desired function value in
the register.
- To program higher CVs:
(1..255)
[48]
- In register CV6, input the number
of the register you want to pro-
gram.
- Then input the desired function
value in register CV5.
(0..255)
[0]
Example:
Set hand-over function to ON (program
(0..255)
[255]
register CV54 to function value 3).
To program:
- Display shows "P --"
- Select register CV6 (press 6).
(0..255)
- Input 54 (register you want to pro-
gram).
- Execute programming (press right
arrow button).
- Display shows "P --"
- Select register CV5 (press 5).
- Input 3 (selected function value)
- Execute programming (press right
arrow button).
When programming with the 55045,
all function values are programmed
directly.
AUTHORIZED SERVICE
Improper service will void your war-
ranty. For quality service, contact
your authorized retailer or one of the
following LGB factory service sta-
tions:
Ernst Paul Lehmann Patentwerk
Reparatur-Abteilung
Saganer Strasse 1-5
D-90475 Nürnberg
GERMANY
Telephone: (0911) 83707 0
Fax: (0911) 83707 70
LGB of America
Repair Department
6444 Nancy Ridge Drive
San Diego, CA 92121
USA
Telephone: (858) 535-9387
Fax: (858) 535-1091
You are responsible for any shipping
costs, insurance and customs fees.
Hint: Information on LGB products
and LGB representatives around
the world is available online at
www.lgb.com
CAUTION! This model is not for chil-
dren under 8 years of age. This
model has small parts, sharp parts
and moving parts. Save the supplied
packaging and instructions.
Products, specifications and avail-
ability dates are subject to change
without notice. Some products are
not available in all markets and at all
retailers. Some products shown are
pre-production prototypes. LGB,
LGB of America, LEHMANN and the
LGB TOYTRAIN logotype are regis-
tered trademarks of Ernst Paul
Lehmann Patentwerk, Germany.
Other trademarks are the property of
their owners. © 2002 Ernst Paul
Lehmann Patentwerk.
15

Werbung

loading

Diese Anleitung auch für:

22660