Classic paraffin 1300
Hole diameter for take
through hole = 45 mm. Use
the exhaust head base plate
as bore template.
Attention! The
Recommended maximum
length for the exhaust
pipe is 0,9 m.
Voor onderdelen of advies ga naar www.hagerbv.nl of bel 0566-622209
1.
Exhaust head 2460 closes by
pressing down and turning
clockwise, opens by turning anti-
clockwise.
2.
Exhaust head is opened for
mounting by pressing in the pin
(2) with a screwdriver etc.
3.
Gasket
Important that the gasket
surfaces and the take through
hole are carefully sealed with
silicone seal.
A.
The exhaust head is mounted on
deck with bolts (4) (M5 x 90) and
nuts (5) with lock washer (5x)
under. Tight the nuts, but not so
hard the base plate deforms.
B.
The mounting plate (7) is fastened
on bulkhead or wall with bolts
(M5x25), with lock washer under
bolt nut. If screws are used the
mounting must be secured with
screws (10x) in the upper holes of
the mounting plate (7).
C.
6
MOUNTING ON BULKHEAD
Place the heater on mounting
plate (7). The cant (7k) helps to
hold up the heater.
Check that the heater exhaust
pipe goes well in the exhaust head
middle pipe.
D.
Cut the exhaust tubes to suitable
length Important – The inner
smoke tube (13) must be cut 5
cm longer than the outer tube
(15). The inner tube must be
pushed well into the bottom of
both heater and exhaust head
pipe (12). The outer tube (15) has
to be secured at both ends with
hose clamps (16/17).
21.
Check that the heater is mounted
so that the reset button (21) of the
overheating thermostat is
accessible for hand.
490130C