Herunterladen Inhalt Inhalt Diese Seite drucken

Gaggenau AC250121 Gebrauchs- Und Montageanleitung Seite 38

Deckenlüftung
Vorschau ausblenden Andere Handbücher für AC250121:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en Installation instructions
¡ Diameter of 150 mm corresponds to ap-
prox. 177 cm².
¡ Diameter of 120 mm corresponds to ap-
prox. 113 cm².
¡ Use sealing strips for different pipe diameters.
¡ Do not use any flat ducts with sharp bends.
Round pipes
Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.
16.9 Installation
Preparing the ceiling
Ensure that the stability of the ceiling is guaranteed
1.
after the cut-outs have been made.
Cover the hob to prevent damage.
2.
Saw a cut-out into the ceiling.
3.
Remove any shavings.
4.
Preparing the appliance
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
Tilt the transport lock slightly upwards and carefully
1.
pull it upwards and out at an angle.
Remove polystyrene residues from the interior of the
2.
appliance.
Remove the grease filters.
3.
To avoid causing damage, do not bend the grease
filters.
Installing the appliance
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
38
The appliance is heavy.
To move the appliance, two people are required.
Use only suitable tools and equipment.
Insert the appliance into the cut-out until you hear
1.
the mounting brackets engage.
Carefully screw in diagonally opposite screws.
2.
5
Tighten the screws one at a time so that the appli-
ance is not wedged in the cut-out.
Note: To ensure that the appliance is not damaged,
3.
do not overtighten the screws.
Carefully tighten screws in succession until the ap-
pliance is flush-mounted on the ceiling.
Connecting the appliance
Press together the cable duct at the sides and re-
1.
move it.
Inhaltsverzeichnis
loading