Quick Reference Guide to RF1058 / CU170
6.
Switching to automatic movements and factory settings
The buttons FLAT, ZGRAV and TV can be used for various saved
positions. Press the respective button briefly (press and release) to move
to that position. The button does not need to be held down.
Proceed as follows to establish communications:
Activate
 Press buttons 13 and 15 for about five seconds simultaneously, the
Press + Release mode is activated.
A successful pairing will be acknowledged.
Deactivate (factory default)
Press buttons 16 and 19 for about five seconds simultaneously, the
Press + Release mode is deactivated. The Press + Hold mode is
activated. The memory positions of ZGRAV and TV are reset to
factory default.
A successful pairing will be acknowledged.
7.
Moving two systems in parallel using a sync cable
CAUTION! Only connect the electrical components when the power
supply is switched off.
Two operating systems can be connected to each other using a sync
cable at the multi-function port. In this way, they can be run
simultaneously.
 Press the Reset/Pairing button on the CU170 (button 6) to move
both systems to their end positions.
 Disconnect the power plug on both systems from the power socket.
 Connect both systems by connecting the proper synchronous cable to
the multi-function port.
 Insert the mains plug from both systems into the power socket.
Parallel operations are possible as soon as both systems are
connected to the power supply.
Both programmed RF remotes can be used to move the systems.
03.04.2017
8.
Moving two systems in parallel using remote radio signals
CAUTION! Only connect the electrical components when the power
supply is switched off.
Two systems can be moved and operated simultaneously (parallel
mode) using one RF1058.
 Press the Reset/Pairing button on the CU170 (button 6) to move
both systems to their end positions.
 Execute the teach-in process first for system 1 (button 1 +19) and
then for system 2 (button 3 +19). Note that the teach-in processes
are always sequential. The teach-in should never be carried out on
two systems at the same time.
The teach-in cannot be execute for a second RF1058 in this mode.
9.
Cleaning and care
This system was designed so that it would be easy to clean.
 Be sure to unplug the power cord of the power socket before you
begin cleaning it!
 Use a dry antistatic cloth to clean the system
Be sure that you do not damage the connecting cables during the
cleaning.
10. Disposal
The system consists of electronic components, cables and metal and
plastic parts. You should observe all corresponding national and
regional environmental regulations when disposing of the system.
The disposal of the end product is regulated in Germany by Elektro-G,
internationally by the EU Directive 2011/65/EC (RoHS), or by any
applicable national laws and regulations. (The end product is not
regulated by the EU Directive 2012/19/EC (WEEE)).
This system should not be disposed of
with normal household waste!
Id-No. 84625(c)
5 / 12

Werbung

loading

Diese Anleitung auch für:

Cu170