INSTALLATION
Drilling the Ceiling/shelf and fi x-
ing the frame
• Use a plumb line to mark the centre of
the hob on the ceiling/support shelf.
• Place the drilling template 21 provided
on the ceiling/support shelf, making
sure that the template is in the correct
position by lining up the axes of the
template with those of the hob.
• Mark the centres of the holes in the
template.
• Drill the holes at the points marked:
• For concrete ceilings, drill for plugs
appropriate to the screw size.
• For hollow brick ceilings with wall
thickness of 20 mm: drill ø 10
mm(immediately insert the Dowels 11
supplied).
• For wooden beam ceilings, drill ac-
cording to the wood screws used.
• For wooden shelf, drill ø 7 mm.
• For the power supply cable feed, drill
ø 10 mm.
Installation
• For the air outlet (Ducted Version), drill
according to the diameter of the ex-
ternal air exhaust duct connection.
• Insert two screws of the following
type, crossing them and leaving 4-5
mm from the ceiling:
• For concrete ceilings, use the appro-
priate plugs for the screw size (not
provided).
• for Cavity ceiling with inner space,
with wall thickness of approx. 20 mm,
Screws 12h, supplied.
• For wooden beam ceilings, use 4
wood screws (not provided).
• For wooden shelf, use 4 screws 12g
with washers 22 and nuts 23, provid-
ed.