Herunterladen Diese Seite drucken

Niko 550-00002 Bedienungsanleitung Seite 29

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

SERVER LED The green
LED lights up
continuously
The orange
LED lights up
continuously
The red LED
lights up
continuously
Using the diagnostics page
Compared to installations with a conventional controller of 2E, the advantage of installations with a connected controller
light is that they can be monitored in detail with the diagnostics page. You can consult it via the programming software.
The diagnostics page is a valuable tool for the installer to detect errors. After all, it allows to quickly analyse the proper
functioning and the set-up of the installation. For example, you can monitor the bus communication live and check which
controls and/or modules have not yet been configured on the bus.
Programming the installation manually
A number of basic functions can be temporarily programmed manually. It can be useful to test the installation or to test or
control the lighting and the roller blinds while the home is still under construction. After programming with the computer, it
is no longer possible to manually program the installation as it might delete or overwrite the saved programming.
Follow the steps below to manually program the installation:
1 Connect the installation to the mains power supply.
2 Press the TEST button and verify that the STATUS LED of each module lights up.
3 Press the PROG button briefly.
The PROG LED lights up and the controller is in manual PROGRAM mode.
Manual programming is only possible if no programming was saved to the controller. If this is the case,
nothing will happen and the PROGRAM LED will not light up.
4 Press on the button of the contact on the module you want to assign to an action button (e.g. a push button or
thermostat). For example, press button one or button two on the dimming module.
5 Press the action button to which you will assign this contact.
This only applies to Niko Home Control action buttons. A potential-free push button connected via the push-
button interface cannot be programmed manually.
The connection with the Niko server is
working properly and the installation was
registered correctly.
The connection with the Niko server is
working properly but the installation was
not yet registered.
No communication possible with the
Niko server. The internet connection
was interrupted or the Niko server is not
accessible.
/
Use the information of the controller
(MAC address and serial number SN
found on the controller and the included
label) to register the installation on
https://mynikohomecontrol.niko.eu.
Please check the internet connection.
If the internet connection is working
properly, contact the Niko customer
service.