OPERATION
General
Use the following procedures to operate a Countertop Heated Well.
WARNING
Read all safety messages in the Important Safety
Information section before operating this equipment.
ELECTRIC SHOCK HAZARD:
• DO NOT use unit to melt or hold ice. Doing so may
cause condensation, creating an electrical hazard and
causing personal injury and/or damage to unit. Damage
caused by condensation is not covered by warranty.
• Turn off and unplug unit when filling with water. Avoid
splashing.
Do NOT use unit to rethermalize food while holding hot food.
NOTICE
Standard and approved manufacturing oils may smoke up
to 30 minutes during initial startup. This is a temporary
condition. Operate unit without food product until smoke
dissipates.
Unit must be allowed to cool down to room temperature
before changing from wet-to-dry or dry-to-wet operation.
Allowing unit to run dry during wet operation or adding
water during dry operation will damage unit.
Hatco Countertop Heated Wells are designed for WET or DRY
operation. Hatco recommends wet operation for consistent
food heating. If the unit is operating wet and is allowed to run
dry, turn it off and allow to cool before adding water.
Power I/O Switch
HW Series Control Panel
Startup
1. If using the well for wet
operation, fill the well with
HOT tap water up to the
"MAX" fill line inside the well.
2. Plug the unit into a properly
g r o u n d e d
e l e c t r i c a l
receptacle of the correct
voltage, size, and plug
configuration. See the
SPECIFICATIONS section
for details.
BURN HAZARD: Some exterior surfaces on unit will get
hot. Use caution when touching these areas.
3. Move the Power I/O (on/off) Switch to the I (on) position.
The indicator light on the switch glows when the unit is on.
4. Turn the Temperature Control to the desired food-safe
temperature setting.
5. Place an empty food pan in the heated well, and allow the
well to preheat for approximately 30 minutes.
Shutdown
1. Move the Power I/O (on/off) Switch to the O (off) position.
The indicator light on the switch will shut off.
Temperature Control
8
"MAX"
Fill Line
CAUTION
"Dry" Indicator Light
HWCEM-1023