Without bypass
 OASE recommends closing the bypass in the following situations:
– Acute problems such as disease or turbidity due to a build-up of bacteria.
– Low flow rates:
Bitron Eco 120 W: < 10000 l/h
Bitron Eco 180 W: < 13000 l/h
Bitron Eco 240 W: < 15000 l/h
How to proceed:
1. Turn the bypass holder counterclockwise until it makes an audible click and remove it from the
outlet.
2. Pull the bypass membrane out of the bypass holder and fit the bypass closure onto the bypass
holder.
– The bypass closure can only be fitted onto the bypass holder in one position.
3. Insert the bypass holder into the outlet and turn it clockwise until it makes an audible click.
– The bypass holder is locked in place.
4. Insert the outlets with flat seals through the holes in the container wall into the distributor.
5. Screw the distributor nuts onto the outlets and hand tighten.
6. Connect the Bitron to the filter pump. (→ Connecting the inlet)
38