The use of smoke alarm devices is gov-
erned by DIN 14676.
Minimum equipment
Bedrooms
Children's bedroom
Guest room
Hallways and all other rooms
which serve as an escape route
Stairwells of family houses
Optimal equipment
All living and hobby rooms
(except in Berlin and Branden-
burg - here such equipment
is also required by law)
Heating and work spaces
Office or workroom
Cellar
Attic
Conditional equipment
Conditional equipment
In kitchens, smoke alarm
devices must only be installed
when false alarms (e.g., caused
by steam) are excluded
EN
User Manual: XSD100 - Smoke Alarm Device
Not recommended
Not recommended
Bathrooms are excluded from
the installation of smoke
alarm devices due to the high
development of steam
4.1 Area to be monitored
Use a device if at least one of the follow-
ing applies:
Monitoring area less than 60 m
and ceiling height of less than 6 m
Ceiling panels (height lower than
20 cm) with joists (ceiling surface
less than 36 m
Use additional equipment if at least one
of the following applies:
Monitoring area greater than 60 m
Ceiling height greater than 6 m
High partial walls
Separating pieces of furniture
2
)
2
,
2
43