Herunterladen Diese Seite drucken

Samoa 365 310 Betriebsanleitung Seite 9

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CONFIGURATION MENU
8. The calibration of valve anticipation factor is performed
by dispensing 1 liter at the working flow rate. This
preset configuration will already appear on the display:
MANUAL SET OF CALIBRATION FACTOR
1. Simultaneously press the "ON" and "SELECT" buttons
until the setup menu is displayed..
3. Press and hold "SELECT" until "Cfactr" flashes in
second line and the current calibration factor is
displayed.
5. Confirm the selection by pressing the "ON" button, the
display returns to the main menu. Pressing the "ON"
button again exits the configuration menu.
Calibration factor calculation
Manual calculation of calibration factor can be
made with following equation:
quantity shown on tdisplay
=
Factor
actual quantity dispensed
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Fig. 14
Fig. 15
Fig. 17
9. Press AUTO and then start dispensing. When the preset
liter is reached, the gun will automatically calibrate the
anticipation by displaying the new value on the screen.
The display shows "done" and automatically returns to
the main menu.
2. Press "SELECT" until the next menu is displayed.
4. Set the value of the new calibration factor. Pressing the
"0.1" quantity button increments the units and the
"10" button decrements the units.
x 1000
Fig. 16
R. 03/22 896 846
EN
9

Werbung

loading