Discharge mode – can be used to reduce and minimize
memory effect and lazy battery effect. Such cell will be
discharged to level of 0.9V. Please note that the cell stays
discharged after completing this process. Further action
will be needed to charge the cell.
Can be also used to discharge (test) primary (i.e. alkaline)
batteries. Please note that you should not try to recharge
primary, non-rechargeable batteries.
Stage 1. Discharging.
Pressing "Display" button will show various information – time,
discharging current, voltage level, momentary capacity in mAh/Ah.
Stage 2. End of discharge process. The charger shows "0
mA" discharge current. No charge is applied automatically.
11