How to disassemble and replace the main and
Hepa filters
ATTENTION DANGER!
When the vacuum cleaner is used to clean up hazardous
substances, the filters become contaminated, thus:
work with care and avoid spilling the vacuumed dust
and/or material;
place the disassembled and/or replaced filter in a
sealed plastic bag;
close the bag hermetically;
dispose of the filter in accordance with the current
laws.
ATTENTION DANGER!
Filter replacement is a serious matter.
The filter must be replaced with one of identical
characteristics, filter surface and category.
Failing this, the vacuum cleaner will not operate correctly.
Main filter replacement
ATTENTION DANGER!
Check the Class of the vacuum cleaner (L - M - H).
Take care not to raise dust when this operation is carried
out. Wear a P3 mask and other protective clothing plus
protective gloves (DPI) suited to the hazardous nature of
the dust collected. Refer to the relative laws in force.
Before proceeding with this operation, turn off the machine and
remove the plug from the power socket.
Disassembly
Remove the hose "A" (Fig. 12) from the lower outlet.
Release stop "B" (Fig. 12) and unscrew filter shaker knob
"C".
Release the two fastening latches "D" (Fig. 12) and
remove lid "E".
Lift filter "F" (Fig. 12), unscrew clamp "G" and remove ring
"H".
Unscrew cage "I" (Fig. 12) and turn the filter upside down.
Cut the plastic clamps "L" (Fig. 12) and detach the cage
from the filter.
Assembly
Fit the filter catch and retention ring of the old filter on to
the new one.
Insert cage "I" (Fig. 12) and fix it to the filter by means of
plastic clamps "L" on the bottom of the filter itself.
Fit the filter into filtering chamber then mount lid "E" (Fig.
12) and lock it in place with the two fastening latches "D".
Fit the filter shaker knob and lock it in the lowered position
by means of the stop so that the filter is kept stretched.
Fit the suction hose on the lower outlet.
Dispose of the filter in accordance with the laws in force.
11/2015
Hepa/Ulpa filter replacement
Version for dust that is hazardous for the health: Class H.
ATTENTION DANGER!
Take care not to raise the dust when this operation is
carried out. Wear a P3 mask and other protective clothing
plus protective gloves (DPI) suited to the hazardous nature
of the dust collected. Refer to laws in force.
Replacing the upstream Hepa filter
Unscrew knob "A" (Fig. 13);
Remove cover "B" (Fig. 13);
Release knob filter "C" (Fig. 13), cover the filter "D" with a
plastic bag and remove everything;
Seal the bag, fit the new filter and hermetically close the
cover.
Note
If the vacuum cleaner is type B1 for zone 11 (version 1 - BIA):
conduct galvanic continuity tests in accordance with the
accident prevention standards (e.g. VBG4 and according to DIN
VDE 0701 part 1 and part 3).
Standard EN 60335-2-69 prescribes inspections at regular
intervals or after all repairs or modifications).
Inspecting and cleaning the motor cooling fan
Periodically clean the motor cooling fan to prevent the electric
motor from overheating, particularly if the appliance is used in a
dusty place.
Seal inspection
Checking the condition of the hoses
Make sure that connecting hose hoses "A", "B" and "C" (Fig. 14)
are in a good condition and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible clogging
along hose "C" (Fig. 14), in outlet and on the baffle in the
filtering chamber.
Scrape outside the outlet and remove the deposited waste as
indicated in figure 14.
Checking the lid seal
If seal "A" (Fig. 15) under lid "D" has become slack, unscrew
screws "B" that lock fastening latches "C" in place and allow
them to slide downwards until lid "D" closes perfectly.
Now tighten locking screws "B" (Fig. 15).
Replace seal "A" (Fig. 15) if an optimum seal cannot be
obtained.
Checking the tightness of filter chamber
If seal "A" (Fig. 16) between the container and filter chamber "C"
fails to guarantee tightness:
loosen the four screws "B" (Fig. 16) that lock filter chamber
"C" against vacuum structure.
Allow filter chamber "C" (Fig. 16) to lower down and relock
screws "B" once it has reached the retention position.
The seal must be replaced if it is torn, cut, etc.
Replace seal "A" (Fig. 16) if the degree of tightness is still not
optimum.