⇒ Press the
or
push-button to select
+
the type of display
S
= setpoint value
U
= time
SuU = setpoint value and time
alternating ever y 5 seconds;
⇒ Press the OK push-button to confirm and
switch to the next adjustment setting.
Maximum floor temperature
40 °c
⇒ Press the
or
push-button to set the
+
maximum adjustable floor temperature;
⇒ Press the OK push-button to confirm and
switch to the next adjsutment setting.
2. Installation instructions
This appliance must be installed (electrical installation) and commisioned by a pproved ser vice technicians in accordance with these
instructions.
All electr ical connection and installation work
must be carried out in accordance with the
VDE (Association of Ger man Electrical
Engineer s) instructions (DIN VDE 0100 T520
A3), the regulations of the responsible
electr icity supply companies, and the relevant
national and regional regulations.
Installation of the switch bo x in rooms with a
bath and/or a shower only outside zones of
protection 1 and 2.
In the event of interruption or a shor t circuit
of the probe line , the heating is switched off.
In the event of a def ect the probe
line may carry mains voltage!
M
+
OK
81,5
Type
Switching capacity
H x W x D
Range of adjustment
Switching difference
Protection class
Protection mode
Length of temperature probe (DIN 44574)
Power reserve
Approvals
Minimum floor temperature
⇒ Press the
or
+
minimum adjustable floor temperature
(difference between the minimum and
maximum floor temperatures at least
5 °C, if this f igure is fallen short of the
maximum value is automatically adjusted);
The minimum floor temperature
does not have any affect on the
„Frost pr otection" operating mode.
⇒ Press the OK push-button to confirm and
switch to the next adjsutment setting.
for the qualified installer
2.1 Installing the temperature probe
Prior to fitting the top covering of the floor, the
temperature probe is to be let into an empty
tube flush with the surface in the foundation
flooring (for example the screed flooring);
see operating and installation instructions f or
temperature controlled floor mat.
2.2 Installing the thermostat
The thermostat is to be inser ted into a
standard commercial UP switch box f or unit
diameters of 55 mm.
The thermostat is to be inser ted as f ollows:
– Pull off the complete changeable frame (7,
8), to do this gr asp the switch frame at the
28,5
44,5
RTF-Z
Sensor characteristics value
~ 16(2) A 230 V
Temperature R [kOhm] U [V]
85 x 81,5 x 44,5 mm
10 °C
ca. 10 ºC . . . 50 ºC
20 °C
1 K
30 °C
ΙΙ, acc . this man ual
40 °C
IP 30
50 °C
4 m
4 days, after 1h of operation
see rating plate
Self learning function
If the self lear ning function is activated, the
RTF-Z switches the floor heating
automatically on in such a manner so that a
moder ate comfor table temperature is
push-button to set the
reached already at the adjusted star ting
times.
⇒ Press push-button
⇒ Press the OK push-button to return to
– Carr y out the electrical connection in
– Inser t the thermostat ( 9) into the switch
– Replace the casing cover (7) and, if
to which the room thermostat should be
connected, has to be obser ved.
9
3,66
2,49
2,43
2,22
1,65
1,92
1,15
1,63
0,82
1,35
oder
, in order to
+
activate the self learning function (Indication
„1") or deactivate (Indication „0").
If the self learning function is deactivated,
the adjusted starting times in the clock
program mean the beginning of the
heating time;
the display setting or press push-button
M to terminate the adjustment mode .
top and bottom;
accordance with the connection diagram
illustrated below or the printed instructions
on the back of the thermostat cover ;
box and screw together ;
appropriate, the switch frame (8) in
addition.
The installation and operating
instructions for the floor heating unit,
8
L
N
RTF-Z
L
LH
N
F F