1. Operating instructions
The RTF-Z digital controller enables individu-
al control of the heating mats. There are four
oper ating programmes.
When connected to the mains electr ical suppl y
the controller switches on and regulates the
floor heating to a preset temper ature. The
„heating oper ating symbol " is displayed.
After setting the time the controller automa-
tically switches to the timer programme .
M
+
OK
1
2
3
4
1 Mode - select an oper ating mode or
function by repeated pressing
2 Reset - restore the factor y setting.
Br iefly depress the flush-fitting push-
button with a non-conductive blunt object.
3 Increase the set value
4 Decrease the set value
5 Confirm the set value
6 Display
Factory settings
Floor temperatures of operating modes
Guide figure
Frost protection
Off-peak temperature
Comf ort temperature
Temperature setting limits
Max. Floor temper ature
Min. Floor temper ature
1.1 First start-up
After connecting to the mains supply, the follo wing displays appear :
for approx. 5 seconds . . .
. . . then alter nately
1 2 3 4 5
88 : 88
6
7
8
8
8
8
8
8
8
8
P
0
6
12
18
24
1.2 Setting the time and day of the week
Press push-buttom M until the
Hour
Push-
button
: 00
00
or
+
OK
for the user and the qualified installer
By means of the self lear ning function of the
RTF-Z, the start-time will be set directl y into
the timer-program, from which the comfor t
temperature will be achiev ed. Due to this, the
star t of the heating-time will be before the
adjusted starting time.
The self-learning-function is activated by the
factory, if wished it can be deactivated within
the adjustment mode .
Displays
Start / end time in the timer program
S1 = 1st star t time
S2 = 2nd star t time
S3 = 3rd star t time
Operating modes
Frost protection
Off-peak temperature
Comfort temper aure
Timer program
5
6
°C
1.0
= ^ approx. 10
1.8
= ^ approx. 18
2.5
= ^ approx. 25
4.0
= ^ approx. 40
1.0
= ^ approx. 10
0
00 : 00
2 . 5
0
0
6
12
18
24
function symbol is displayed.
0
6
12
18
24
Min utes
E1 = 1st end time
E2 = 2nd end time
E3 = 3rd end time
2 . 5
1 2 3 4 5
S
S
1
1
0
6
Value indicator
Setpoint floor temperature
(Guide figure, e.g. 2.5 = approx.
25 °C) or time
Timer program switching times
comfort temperature
P1
S1
Mo - Fr
P2
Sa - Su
P3
S1
3
6
12
18
24
probe defective or not connected
6
12
18
24
Push-
Day of the week
button
1
or
+
OK
Switching ON & OFF
To switch off, press the M button and hold
for 3 seconds, the display will then show OFF.
To switch on again press and hold the M
button for 3 seconds. The controller will
switch on again to its most recent setting.
In the off position frost pr otection is
not provided.
Days of the week
1-5 = Monday - Fr iday
6+7 = Saturday + Sunday
Functions
Heating operating
6
7
Time
P
P
Program selection
2
2
P
P
12
18
24
Timer programs
P1 = Progr am 1
P2 = Progr am 2
P3 = Progr am 3
Time segments of timer
Comfor t temperature
Off-peak temperature
otherwise
Off-peak temperature
00
00
00
S2
6
9
E1
16
00
S1
7
00
00
12
14
00
00
E1
S2
E2
S3
6
9
9
15
6
12
time
Push-
button
or
+
OK
00
23
E2
00
23
E1
00
00
E3
17
23
21
18
24
5