2. Operating mode
all device functions are active.
By moving the mushroom knob, the device is switched from the idle mode to the
operating mode.
If the indexing plunger with status sensor is connected to a receiver, such as a
Gateway, the operating mode remains permanently active.
If the indexing plunger with status sensor is not connected to a receiver and is
not moved, the device switches back to the idle mode after 30 seconds.
5.3 Commissioning
5.3.1 Establishing the radio link
To link an indexing plunger with status sensor to a receiver (pairing), proceed
as follows:
1. Move the mushroom knob of the device to establish the operating status.
2. The LED in the mushroom knob begins to blink (1x per second)
 The device sends a signal and attempts to link with a receiver. The device
name is "KIPP-Plunger"
3. The link must be confirmed at the receiver.
 When the link is established and confirmed at the receiver, the LED on the
mushroom knob goes out.
4. mechanical actuation of the indexing plunger
 By the first mechanical actuation of the connected indexing plunger, the
actuation status is teached and transmitted to the receiver.
INFO!
Ensure clear identification
For clear identification, make sure that only the indexing plunger to be linked is in
pairing mode (blinking LED).