Herunterladen Diese Seite drucken

Blaupunkt 5DA36450 Gebrauchs- Und Montageanleitung Seite 24

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Risk of fire!
Grease deposits in the grease filter may
catch fire. The specified safety distances
must be observed in order to prevent an
accumulation of heat. Observe the
specifications for your cooking appliance. If
gas and electric hobs are operated
together, the largest specified distance
applies.
Only one side of the appliance may be
installed directly next to a high-sided unit or
a wall. The distance between the appliance
and wall or high-sided unit must be at least
50 mm.
Risk of injury!
Components inside the appliance may
have sharp edges. Wear protective gloves.
The appliance may fall down if it has not
Risk of injury!
been properly fastened in place. All
fastening components must be fixed firmly
and securely.
The appliance is heavy. To move the
Risk of injury!
appliance, 2 people are required. Use only
suitable tools and equipment.
Risk of electric shock!
Components inside the appliance may have
sharp edges. These may damage the
connecting cable. Do not kink or pinch the
connecting cable during installation.
Risk of electric shock!
It must always be possible to disconnect
the appliance from the electricity supply.
The appliance must only be connected to a
protective contact socket which has been
correctly installed. If the plug is no longer
accessible following installation of the
appliance, or a fixed connection is required,
an all-pole isolating switch must be present
on the installation side with a contact gap of
at least 3 mm. The fixed connection must
only be installed by an electrician.
Danger of suffocation!
Packaging material is dangerous to
children. Never allow children to play with
packaging material.
24
General information
Exhaust air mode
:
Risk of death!
Risk of poisoning from flue gases that are drawn back in. The
exhaust air must not be conveyed into a functioning smoke or
exhaust gas flue or into a shaft which is used to ventilate
installation rooms that contain heating appliances. If the
exhaust air is to be conveyed into a non-functioning smoke or
exhaust gas flue, you must obtain the consent of the heating
engineer responsible.
If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.
Exhaust duct
Note: The appliance manufacturer does not provide any
warranty for faults attributable to the pipe section.
The appliance achieves its optimum performance by means
of a short, straight exhaust air pipe and as large a pipe
diameter as possible.
As a result of long, rough exhaust air pipes, many pipe bends
or pipe diameters that are smaller than 150 mm, the optimum
extraction performance is not achieved and fan noise is
increased.
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Round pipes
An inner diameter of 150 mm, but at least 120 mm, is
recommended.
Flat ducts
The inner cross-section must correspond to the diameter of the
round pipes.
150 mm diameter, approx. 177 cm
120 mm diameter, approx. 113 cm
Flat ducts should not have any sharp deflections.
Use sealing strips for different pipe diameters.
G e n e r a l i n f o r m a t i o n
2
2

Werbung

loading

Diese Anleitung auch für:

5da36251