Rotary switch
Device OFF
Device ON
Switching on the device
1. Connect the mains plug.
2. Switch on the device at the turn switch.
Cleaning mode
1. Perform cleaning.
Switching off the device
1. Switch off the device at the turn switch.
2. Pull out the mains plug.
Each time after use
1. Empty the container.
2. Vacuum off the inside and outside of the device and
clean with a moist cloth.
3. A vacuum cleaner with at least the same or better
classification must be used for vacuuming the device.
4. Remove the accessories and, if necessary, flush
with water and allow to dry.
Folding the push handle in/out
1. Release the push handle fastening screws and ad-
just the push handle.
Storing the device
1. Store the suction hose and mains cable as shown in
the illustration.
Illustration G
2. Store the device in a dry room and secure it against
unauthorised use.
Transport
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transporta-
tion.
When transporting the device, ensure that it is securely
fastened.
The following measures must be taken for the dust-free
transport of the device:
1. Clean the suction hose and accessories with a
damp cloth.
2. Close the suction connection, see wet vacuum
cleaning.
3. Remove the suction hose with floor nozzle from the
support. Carry the device by the carrying handle and
suction pipe.
4. When transporting the device in vehicles, secure it
to prevent it from slipping or overturning in accord-
ance with the respective valid guidelines.
Storage
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
The device may only be operated indoors.
14
Care and service
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Dust extraction machines are safety devices for the pre-
vention or elimination of hazards according to the Ger-
man DGUV regulation 1 (German accident prevention
regulation, principles of prevention).
ATTENTION
Care agents containing silicone
These can attach plastic components.
Do not use care agents containing silicone for cleaning.
● You can perform basic maintenance and care work
yourself.
● Clean the surface of the device and the interior of
the container regularly with a moist cloth.
Replacing the flat fold filter
1. Open the filter cover.
2. Remove the filter frame.
Illustration H
3. Remove the flat fold filter.
4. Dispose of the used flat fold filter in accordance with
statutory regulations.
5. Remove any dirt deposits from the clean air side.
6. Clean the filter frame and the supporting surface of
the filter frame with a damp cloth.
7. Fit the new flat fold filter. During insertion, ensure
that the flat fold filter is flush on all sides.
8. Insert the filter frame.
9. Close the filter cover until it audibly latches into
place.
Change the candle filter
1. Open the filter cover.
2. Take out the candle filter (special accessories).
Illustration I
3. Dispose of the used candle filter (special accesso-
ries) in accordance with statutory regulations.
4. Remove any dirt deposits from the clean air side.
5. Clean the candle filter frame with a damp cloth.
6. Insert the new candle filter (special accessories).
7. Close the filter cover until it audibly latches into
place.
Changing the fleece filter bag
1. Close the suction connection, see wet vacuum
cleaning.
Illustration E
2. Unlock and remove the suction head.
3. Pull the fleece filter bag out to the rear.
Illustration F
4. Fold in the cap and seal the fleece filter bag tight.
5. Dispose of the used fleece filter bag in accordance
with statutory regulations.
6. Fit the new fleece filter bag.
7. Fit and lock the suction head.
Cleaning the cooling air filter
1. Vacuum the cooling air filter from the outside (when
installed) at regular intervals.