Herunterladen Diese Seite drucken

Volkswagen AFC-200-LH-DE Service Seite 75

Werbung

Group
Parameter
OCPP
StopTransactionOnInva-
lidId
OCPP
StopTxnAlignedData
OCPP
StopTxnSampledData
OCPP
TransactionMessageAt-
tempts
OCPP
TransactionMessage-
RetryInterval
Description
optional
Whether the Charge Point
will stop an ongoing trans-
action when it receives a
non- Accepted authorizati-
on status in a StartTran-
saction.conf for this trans-
action
Note: Only value "true" is
supported. Changed will
be rejected until SW 5.0.
optional
Clock-aligned periodic
measurand(s) to be inclu-
ded in the TransactionDa-
ta element of StopTran-
saction.req MeterValu-
es.req PDU for every Clo-
ckAlignedDataInterval of
the Transaction
Supported values: OCPP
Measurand Mapping
recommended
Sampled measurands to
be included in the Trans-
actionData element of
StopTransaction.req PDU,
every MeterValueSam-
pleInterval seconds from
the start of the charging
session.Supported values:
OCPP Measurand Map-
ping
optional
How often the Charge
Point should try to submit
a transaction-related mes-
sage when the Central
System fails to process it.
optional
How long the Charge Point
should wait in seconds be-
fore resubmitting a trans-
action-related message
that the Central System
failed to process.
11 Konfiguration durch den Betreiber
Erstinbetriebnahme 06.2023
Default Va-
Mapping to con-
lue
fig_file.json
true
ocpp.stop_trans_on_
invalid_id
()
ocpp.stop_txn_alig-
ned_data
(Energy.Acti-
ocpp.stop_txn_sam-
ve.Import.Re-
pled_data
gister, Cur-
rent.Offered,
Power.Offer-
ed)
5
ocpp.trans_mesg_at-
temps
20
ocpp.trans_mesg_ret
ry_interval
3
69

Werbung

loading

Diese Anleitung auch für:

Afc-200-lh-eu