Herunterladen Diese Seite drucken

Volkswagen AFC-200-LH-DE Service Seite 73

Werbung

Group
Parameter
OCPP
ConnectionTimeOut
OCPP
HeartbeatInterval
OCPP
LocalAuthorizeOffline
OCPP
LocalPreAuthorize
OCPP
MeterValuesAlignedDa-
ta
Description
recommended
Interval in seconds from
beginning of status: 'Pre-
paring' until incipient
Transaction is automatical-
ly canceled, due to failure
of EV driver to (correctly)
insert the charging cable
connector(s) into the ap-
propriate socket(s). The
Charge Point SHALL go
back to the original state,
probably: 'Available'. Note:
A value lesser or equal to
zero ( value <= 0) means
that no time out timer
SHALL be started.
optional
Interval of inactivity (no
OCPP exchanges) with
central system in seconds
after which the Charge
Point should send a Heart-
beat.req PDU.
A HearbeatInterval confir-
mation triggers synchron-
ization of the system's
time with the central sys-
tem's time contained in the
confirmation (see
AFC-274).
recommended
Whether the Charge Point,
when offline, will start a
transaction for locally-au-
thorized identifiers.
optional
Whether the Charge Point,
when online, will start a
transaction for locally-au-
thorized identifiers without
waiting for or requesting
an Authorize.conf from the
Central System.
recommended
Clock-aligned measu-
rand(s) to be included in a
MeterValues.req PDU,
every ClockAlignedDataIn-
terval seconds.
Supported values: OCPP
Measurand Mapping
11 Konfiguration durch den Betreiber
Erstinbetriebnahme 06.2023
Default Va-
Mapping to con-
lue
fig_file.json
60
ocpp.connecti-
on_timeout
86000
ocpp.heart_beat_in-
terval
false
ocpp.local_auth_off-
line
false
ocpp.local_pre_auth
(SoC)
ocpp.meter_va-
lue_aligned_data
3
67

Werbung

loading

Diese Anleitung auch für:

Afc-200-lh-eu