Rectifying Faults
Problem
External USB device cannot be charged using the USB
port.
Battery charge indicator (3 LEDs) is flashing quickly.
Temperature of the battery is above the operating tem-
perature range. / Battery adapter is overloaded.
A Charge the battery.
B See details in "Technical Data". Some external USB devices cannot
be charged with this battery adapter despite being consistent with
the technical data.
C Remove the battery (4) from the battery adapter (1) and re-insert. If
necessary, allow devices to cool down.
D Connect the charging cable of the external USB device to the USB
port (3) on the battery adapter (1).
1 609 92A 97A | (15.01.2024)
Remedy
A/B/C/D
B/C