8.2 Test mode
1. Press the test key (3) and hold it down during the test period.
2. Place the test tip by the object that you wish to test.
3. The test gauge (2) will light up and an acoustic signal will sound when a magnetic field has
been detected. If the display lightens up briefly, this might be caused by adjoining compo-
nents.
4. When the test key is released, the tester is turned off.
8.3 LED Torch
Press the switch (5). The LED lamp (6) on the back of the tester lights.
9 Cleaning
The tester is maintenance-free, apart from the need to replace the batteries and occasional
cleaning. Use a dry, clean, lint-free, antistatic cloth to clean the device. Do not use any abrasive
or chemical agents or detergents containing solvents.
Periodically, check the technical safety of the tester.
It can be assumed that correct operation is no longer possible if:
– the device is visibly damaged,
– if the device was stored under unfavourable conditions for a long period of time
– if it was exposed to extraordinary stress caused by transport
– the test function, described above, does not work as it should.
Do not try to open the casing, apart from the battery compartment.
10 Disposal
10.1 Product
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should not be disposed of as
unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
in our Conrad offices

at the Conrad collection points

at the collection points of public waste management authorities or the collection points set

up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
10.2 (Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them separately from the
product. According to the Battery Directive, end users are legally obliged to return all spent
batteries/rechargeable batteries; they must not be disposed of in the normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled with
this symbol to indicate that disposal in household waste is forbidden. The abbrevia-
tions for heavy metals in batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead
(name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our
stores or wherever (rechargeable) batteries are sold. You thus fulfil your statutory obligations
and contribute to environmental protection.
Batteries/rechargeable batteries that are disposed of should be protected against short circuit
and their exposed terminals should be covered completely with insulating tape before disposal.
Even empty batteries/rechargeable batteries can contain residual energy that may cause them
to swell, burst, catch fire or explode in the event of a short circuit.
11 Technical Data
Operating voltage ................................. 2 x alkaline micro batteries (AAA)
Power consumption .............................. approx. 32 mA
Magnetic fields ...................................... AC, DC (also permanent magnets)
Detectable inductance (H = Henry) ...... 63 H, 98 H, 401 H, 810 H
Weight .................................................. 48 g
Protection class .................................... 2 (double or reinforced insulation)
Working temperature range .................. -10 to +50 °C
Relative humidity .................................. < 95 % rh (non-condensing)
Storage temperature ............................. -10 to +50 °C
Max. operating altitude ......................... 3000 m
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
*2986823_v1_1123_02_dm_mh_EN

Werbung

loading

Diese Anleitung auch für:

2986823