Fixing options (optional)
1
3
2
1. First insert the sensor (1) into the
adapter (2) until the end stop.
2. Then fix the sensor using the
screws (3) as shown.
Ensure a tight and safe fit.
Make sure that no metallic compo-
nents are in the immediate vicinity
of the sensor or approach the sen-
sor during operation (especially no
metal rings which enclose the sen-
sor)! This might affect the function-
ing of the sensor.
Fixing elements such as screws,
clamps and similar small metal parts
(< 20 x 20 x 30 mm) have no impact
on the sensor. For safe functioning the
adapter (1) must consist of non con-
ductive plastic.
12
by means of latching clamp
(enclosed)
1
3
2
1. Fix the latching clamp (3) to the
adapter (2) as shown.
2. Carefully latch the sensor (1) as far
as it will go.
x
A
1
A = metallic objects
x = min. 10 mm
y = min. 45 mm
y