9.2 Maintenance filter element
The CLEAR PRO RD domestic water unit and also the CLEAR PRO R backwash filter are designed in
such a way that the filter element can be cleaned or replaced after disassembly (according to chapter
9.1 Maintenance of pressure reducer, Fig. 9.1 to 9.4).
Proceed as follows:
Fig. 9.9
/
Fig. 9.9: lead the CONEL mounting spanner [b] (see
chapter 12, Spare parts) over the filter cup [a] from
below
/
let the rib contour of the filter cap [a] engage in the
recesses of the mounting spanner [b]
/
unscrew the filter cap [a] from the housing in the
direction of the arrow
During assembly, make sure that a
tightening torque in the range of 40 to 45 Nm
is maintained.
/
Fig. 9.10: With the filter cup [a], the ball valve [c] as
well as the washer [d] and cylindrical pressure
spring [e] come off
/
the filter element [f] is loosened, it can be pulled out
of the housing and cleaned
/
if necessary, it can be exchanged;
the CONEL replacement filter element [f] (see
chapter 12, Spare parts) is provided for this purpose
[b]
[a]
[c]
[f]
[a]
[e]
[d]
[c]
Fig. 9.10

Werbung

loading

Verwandte Produkte für Conel CLEAR PRO RD 1 1/2'' - 2''

Diese Anleitung auch für:

Clear pro rd 3/4'' - 1 1/4''