Herunterladen Diese Seite drucken

Dell PowerEdge C6220 II Handbuch Zum Einstieg Mit Dem System Seite 14

Vorschau ausblenden Andere Handbücher für PowerEdge C6220 II:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
All manuals and user guides at all-guides.com
Supply voltage
Frequency
Current consumption
Technical Specifications
Power
NOTE: The system doesn't support a mixed installation of 1200 W and 1400 W power supply
units.
NOTE: Both the 1200 W and 1400 W PSUs are hot swappable, and they can support hot swap in
any condition if the system has the power throttling feature.
AC power supply (per power supply)
Wattage
Voltage
Heat dissipation
Maximum inrush current
Wattage
Voltage
Heat dissipation
Maximum in-rush current
Getting Started With Your System
100-240 V AC with 1200 W Power
Supply Unit
200-240 V AC with 1400 W Power
Supply Unit
50/60 Hz
12-8 Amps with 1200 W Power Supply
Unit
9 Amps with 1400 W Power Supply
Unit
1200 W
100-240 VAC, 50/60 Hz, maximum input
current: 12.0-8.0 Amps
NOTE: For 1200 W power supply, output 1200 W is for
high line (input 200-240 VAC), output 1023 W is for low
line (input 100-120 VAC).
4016.251 BTU/hr maximum
Initial In-rush Current cannot exceed 55
Amps (peak). Secondary In-rush Current
cannot exceed 35 Amps (peak).
1400 W
200-240 VAC, 50-60 Hz, maximum input
current: 9.0 Amps
6024.376 BTU/hr maximum.
Initial In-rush Current cannot exceed 55
Amps (peak). Secondary In-rush Current
cannot exceed 25 Amps (peak).
|
12

Werbung

loading