3.
Position the pump underdeck and check fl ow direction.
4.
Work the rubber gaiter up through the hole until its fl ange rests on the deck.
5.
Place deck plate cover on top of the deck and secure with the 4 screws provided into the pump body.
6.
Attach 1" I.D. (25 mm) smooth bore reinforced hose with stainless steel wormdrive hose clips. Tighten the clips to prevent air
leaks.
7.
With thru-hull discharge, make sure that the discharge point is above the water line.
8.
Check the installation for air leaks, correct priming and discharge.
7. INSTRUCTIONS FOR USE
The Whale Compac 50 ensures effi cient throughput with an easy pumping action. Full even strokes will obtain the best results. Two clips
are provided for storing the handle when the pump is not in use.
Output
At 45 Strokes/Min
US Gal/min
9
Litres/min
32
8. MAINTENANCE
This Whale® Compac 50 is designed to only require minimal maintenance.
WARNING: Before servicing, turn off the power and drain water from system.
Optimal Performance
For optimal performance, regular inspection of the pump for debris and damage is recommended.
Rubber components are perishable and susceptible to damage. They should be inspected periodically and replaced as necessary
The following service kits are available, please visit www.whalepumps.com for more information or for details of a local retailer:
AK8035 - Whale Compac 50 - diaphragm, valves and fi xings
AS0353 - Clamping Ring Kit
AS0355 - Spare Handle
Changing the Diaphragm and Valves
Diaphragm:
1.
Slacken and remove the clamping ring screws and remove clamping rings (hoses may be left attached).
2.
Remove clamping plate screw and clamping plate.
3.
Replace diaphragm ensuring the centre portion of the diaphragm projects into valve chamber.
4.
Check diaphragm is "seated" in the cover grooves.
Valves:
1.
Unscrew the 4 self tapping screws at the base of the inlet/outlet nipples (hoses can be left attached).
2.
Remove and replace the valves ensuring that they are correctly seated in the pump body groove.
3.
Replace the nipples in their mounting position and secure in place.
9. TROUBLESHOOTING
Pump fails to prime or chokes:
Check inlet hose connection is airtight and does not collapse during the suction stroke.
Inspect inlet and outlet valves for blockages. Clear with fi nger or screwdriver and test.
Solid objects in the body of the pump should not prevent operation but must be removed to prevent damage.
10. WINTERIZING
NOTE When winterizing, fully drain system.
Whale® does not cover damage, caused by the system not being not fully drained for winterizing.
11. SERVICE SUPPORT DETAILS
For installation or service advice please contact Whale® Customer Support:
UK Tel: +44 (0)28 9127 0531
USA Tel: 1 802 367 1091
12. WARRANTY
Whale® Compac 50 is guaranteed for 5 year from date of purchase. The rubber components are guaranteed for 1 year from date of
purchase. Please refer to the enclosed document for details of our Statement of Limited Warranty.
13. PATENTS AND TRADEMARKS
Whale® is a registered trademarks of Munster Simms Engineering limited (also trading as Whale® Seaward Inc).
14. APPROVALS
This product complies with all relevant European directives and standards. Please contact Whale® if further details are required.
Copyright Whale 2020 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE®, is a registered
trademark of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. Whale's policy is one of continuous
improvement and we reserve the right to change specifi cations without prior notice. Illustrations are for guidance purposes only. Neither the
accuracy nor completeness of the information contained in this or any product literature is guaranteed by the Company and may be subject
to change at its sole discretion.
Please note: Performance data is based on factory tests and is typical
At 70 Strokes/Min
of what may reasonably be achieved. Actual performance may vary
9.2
depending on installation and operating conditions.
35
Email: info@whalepumps.com
Email USA: usasales@whalepumps.com
AS0356 - Whale Compac 50 Ivory Deckplate Kit
AS0358 - Whale Compac 50 Black Deckplate Kit
AS0364 - Whale Compac 50 White Deckplate Kit

Werbung

loading

Diese Anleitung auch für:

Bp0350Bp0350bBp0352bMh0360Mh0364