Connect each PV module with the DC input ca-
bles of the microinverter.
Step 11. Switch on the PV system
Ensure all connection is completed. Turn on the
air switch. In a short time, you shall see the sig-
nal light blinking in green.
Step 12. (Optional) For the monitoring device
(EnverBridge) installation, scan this QR code.
EnverBridge Installation
4. Wi-Fi Configuration
Note: Please position the microinverter as close
as possible to the router.
The microinverter has built-in Wi-Fi modular and
can be connected the router directly.
Scan the QR code below or search for EnverView
on your app store to download.
a. Open EnverView and click Wi-Fi. Select EVT.
b. Select a 2.4GHz Wi-Fi network, and return to
the app. Enter Wi-Fi password. Allow Enver-
View to use your location, or you will fail to
configure the Wi-Fi.
-
Note:
1. Ensure that the Wi-Fi name do not contain , ;
= or other special characters.
2. Check the Wi-Fi password, including spaces
and special characters.
3. Ensure the Wi-Fi your phone connected to is
2.4GHz, and the connection between the router
and the Internet is in good condition.
c. Connect the network of the same name as
your EVT's SN. Return to the app. Allow Enver-
View to access your local network. If not, it
will cause configuration failure.
5
Note: When configuring Wi-Fi, make sure you
keep staying on the current network.
d. Click Configuration and wait for success.
Note: If the setting is not successful, wait for 5
more seconds. Click Configuration again and
check that the microinverter is as close to the
router as possible.
5. Warranty Policy
Please register your product to obtain full war-
6
ranty, or only a 2-year warranty is granted.
Register Your Product
6. Microinverter Safety
*DANGER: Risk of electric shock. Do not attempt
to repair the Envertech Microinverter by yourself;
it contains no user-serviceable parts. If the mi-
croinverter fails, contact your distributor or En-
vertech customer service to obtain an RMA (re-
turn merchandise authorization) number and get
the replacement. Tampering with or opening the
Envertech Microinverter will void the warranty.
*DANGER: Risk of fire. The DC conductors of the
PV module must be labeled "PV Wire" or "PV
Cable" when paired with the Envertech Microin-
verter.
*WARNING: Make sure the DC operating voltage
range of the PV module is within the allowable
input voltage range of the Envertech Microin-
verter.
*WARNING: The maximum open circuit voltage
of the PV module must not exceed the specified
maximum input DC voltage of the Envertech
Microinverter. Using electrically incompatible PV
module voids Envertech's warranty.
*WARNING: Risk of equipment damage. Install
the microinverter under the PV module to avoid
direct exposure to rain, UV, and other harmful
weather events. Do not mount the microinverter
upside down. Do not expose the AC or DC con-
nectors to rain or condensation before mating
the connectors.
*WARNING: Risk of equipment damage. The
Envertech Microinverter is not protected from
damage due to moisture trapped in the cabling
systems. Never mate microinverters to cables
that have been left disconnected and exposed to
wet conditions. This will void the Envertech war-
ranty.
*WARNING: Risk of equipment damage. The
Envertech Microinverter functions only with a
standard, compatible PV module with appropri-
ate fill-factor, voltage, and current ratings. Un-
supported devices include smart PV modules,
fuel cells, wind or water turbines, DC generators,
7