4.4 Safety information
the outer surfaces, door, handles, glass panel
and flue pipe will become hot during operation!
Appropriate gloves precautions must be taken.
4.5 Installation instructions
The standard product is delivered assembled
ready for connection and must be sealed to the
existing chimney using a short, straight,
horizontal connecting piece. the stoves can be
connected either from above or from the rear.
Building and fire regulations must be observed.
Contact a registered installer for advice in
advance.
4.6 Combustion air supply
Before operating the stove, an adequate supply
of air for combustion must be ensured and the
room must be well ventilated.
Stoves are usually operated as non-room sealed
heating appliances which draw combustion air
from the room where the appliance is fitted.
For this reason, it must be ensured that the
room is well ventilated
Tight-closing windows and doors can limit the
supply of combustion air with adverse effects
on the flue draught. This can be detrimental to
health and possibly compromise safety. Air
consumers such as extractor fans or fans
installed together with heating appliances in
the same room or room air connection can
adversely effect the function of the stove.
These must not be operated at the same time
as the stove. An air balance must be established
to ensure that the stove functions perfectly
Combustion air can also be provided directly via
a duct from outside, or indirectly via a vent in
the outer wall of the room where the stove is to
be placed. The amount of combustion air used
for combustion is approximately 25 m3/h
Option 1.
External combustion air supply from
below.
Option 2.
External combustion air supply rear.