4 Stove installation
To ensure that your stove gives you years of good service, please read these instructions fully and
carefully.
4.1 Floor loading
The weight of the stove and chimney must not exceed the maximum permissible floor loading
capacity. The use of a non-combustible floor plate will distribute the weight of the stove over a larger
area.
4.2 Floor conditions
Prior to installation, consult a registered installer or chimney sweep. when the stove door is open,
there is a risk of sparks flying over the specified floor plate area.
To protect the floor from any embers the stove must be placed on a hearth plate. If the floor under the
stove is flammable, it must be protected by a non-flammable material which covers at least 500 mm to
the front and 300 mm on each side. The hearth plate can consist of natural stone, concrete or painted
steel.
4.3 Safety clearances to combustible materials
Position the stove on a hearth plate and check that the installation distances given in the
diagrams are met. The minimum distance between the stove opening and combustible parts
of the furniture or décor must be at least 1 m.
When top connecting a steel flue please refer to the relevant manufacturer's installation instructions.
Observe the safety distances to combustible material that steel flues require