Installation distance to walls and ceiling
Combustible roof
Combustible wall
Fire-retardant wall of
brick or concrete
*To prevent the discolouring of painted fire walls, we recommend a side distance the same as for the combustible wall.
Position the stove on a hearth plate and check
that the installation distances given in the
diagrams are met. The minimum distance bet-
ween the stove opening and combustible parts
of the building or décor must be at least 1 m.
When top connecting a steel flue please refer
to the relevant manufacturer's installation
instructions. Observe the safety distances to
combustible material that steel flues require.
A =
B =
C =
D =
Permitted area
for combustible
parts of the
building
Permitted area for combustible material
Fire-retardant wall of
brick or concrete
200*
445*
GB25
E4 and E4-LS
height from floor to top flue connection, Ø150
height from floor to c/c smoke outlet rear, Ø150
distance from back to c/c air inlet, Ø64
distance from back to smoke outlet rear, Ø150
400
300
200
100
Combustible wall
500
745