1. Regulatory information
It is recommended to consult a registered installer prior to installation.
The registered installer will inform you about the locally applicable regulations and issue the necessary
permit for operation of the stove following correct installation.
The installation of the stove must take place in accordance with each country's laws and regulations. All
local ordinances, including those that refer to national and European standards, must be complied with
when products are installed.
The installation can only be taken into use after it has been checked by a qualified inspector.
A rating plate made of a heat-resistant material is fixed to the heat shield. This provides information on
identification and documentation of the product.
The room or space containing the stove shall have a permanent air supply to ensure proper
combustion, to determine correct amount of air supply use current edition of Building Regulations.
Remember to use only for the appliance recommended fuel as wood logs.
2.Technical data
Output: 3--6 kW Nominal output: 4 kW
Efficiency level Up to 76 %
Model E4
Weight (kg): 45; Width (mm): 370; Depth (mm):395; Height (mm):455
Model E4-LS
Weight (kg): XX; Width (mm): 370; Depth (mm):395; Height (mm):555
The connector's inner diameter is Ø125 mm
Type approved in accordance with:
European standard EN-13 229 (DE/A) DINplus, Art. 15a B-VG RRF-29 11 2751
Technical data in accordance with EN 13229
Nominal heat output: 4 kW
Efficiency: 76 %
CO emissions (13% O2): 0.1 %
OGC emissions (13% O2): 116 mg/Nm3
DIN Plus dust emissions (13% O2): 22 mg/Nm3
Flue gas temperature: 240 °C
Flue gas mass flow: 4.2 g/s
Chimney draught, EN 13229: 12 Pa
Recommended draught with smoke outlet: 14-17Pa;
Fuel consumption: 1.5 kg/h
Operation: Intermittent