Herunterladen Diese Seite drucken

VOLTCRAFT MSO-2072USB Bedienungsanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

connection and installation of the mso
Connect the power adapter to the MSO at connection "1" and the USB cable at connection
"2" and to your computer. The measurement device will be detected automatically by your
operating system. Then, follow the on-screen instructions.
startinG the measUrement proGram
Establish a USB connection between the oscilloscope attachment and your computer.
Start the measurement program (included in the scope of delivery) on your computer.
The start screen of the measurement software appears, and the MSO is initialized. If neces-
sary, select your model. The measurement software is now ready to use.
Using the "AUTO" software button, all parameters on the MSO are automatically adjus-
ted so that an optimal signal representation appears on the screen.
maintenance and cleaninG
The product is maintenance-free.
In order to ensure the accuracy of the measurement device over a long period, it is recom-
mended to have the device calibrated once a year.
Never clean the product when it is turned on. Use a clean, dry, soft cloth for cleaning. Do not
use aggressive cleaning agents, as these can cause discolouration. Do not press too strongly
on the surface when cleaning, to prevent scratch marks.
disposal
D ispose of an unserviceable product in accordance with the relevant statutory
regulations.
technical data
Measurement inputs . ............................2 analogue channels, 16-channel logic analyzer
Bandwidth . ............................................70 MHz
Input impedance . ..................................1 MOhm
Input resistance ...................................25pF
Input coupling .......................................AC/DC/GND
Vertical displacement . ...........................10 mV/div – 5 V/div
Precision . ..............................................± 3 %
Rise time . ..............................................5 ns
Vertical resolution .................................8 Bit
Vertical storage depth . ..........................10k – 16M je Kanal
Max. input voltage ................................40 V/DC or 40 Vp/AC
Test probes . ..........................................2 x (je 1:1/10:1)
Sampling rate .......................................200 MS/s
Time basis ............................................5 ns/div – 1000 s/div (1-2-5 sequences)
Precision of time basis . .........................± 50 ppm
Autoset .................................................Yes
Power supply . .......................................8 – 36 V via mains adapter (100 - 240 V/AC)
Power consumption . .............................Max. 1 A
Interface . ...............................................USB 2.0
Cable length for mains adapter ............110 cm
Cable length for test probes .................106 cm
Weight ..................................................1 kg
Dimensions . ..........................................255 x 190 x 45 mm (L x W x H)
measurement types
Voltage measurement
Time measurement
Cursor measurement
Wellenform
All manuals and user guides at all-guides.com
Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg,
Vrms, Vcrms, Preshoot, Overshoot
Frequency, periods, rise time, fall time, positive
width, negative width, switched-on time
Horizontal, vertical, Track, AUTO measurement
+, -, X, /, FFT, Invert
Voltage range
10 mV to 5 V/div
100 mV to 50 V/div
1 V to 500 V/div
10 V to 5000 V/div
100 V to 50000 V/div
200 mV to 100 V/div
trigger
Source
Selection
Input X-axise
Input Y-axis
Mode
logic analyzer
Input impedance
Input voltage range
Sampling rate
Bandwidth
Compatibility
Storage depth
G
legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© copyright 2014 by conrad electronic se.
probe head ratio (adjustable)
1:1
10:1
100:1
1000:1
10000:1
20:1
CH1, CH2, D0-D15, EXT
Edge, Pulse, Video, Alternative
CH1
CH2
Auto/Normal/Single
200 kΩ
60 V DC/AC
100 MHz
10 MHz
TTL, LVTTL, CMOS, LVCMOS, ECL, PECL, EIA
10K-64M totally or 10K-16M per channel

Werbung

loading

Diese Anleitung auch für:

1086338