blue PiraT2 Release Notes
Firmware/Client V1.8.1, Datum: 25.06.2013
5552 Wrong marker sorting
after conversion
5554 Wrong conversion to
.BLF
5556 [PreReleases 1.8.1 only]
Trigger event "CAN
receive" wrong
5599 [PreReleases 1.8.1 only]
Data Logger shuts down
if Ethernet and VLAN are
used
5607 [PreReleases 1.8.1 only]
Data logger does not
record short sessions
5638 No clean reset after after
low voltage
5745 Download-crash with
error message "Can't
read inflate stream"
2.5 Fixed Bugs (not yet verified)
All fixed bugs have been verified.
2.6 Known Bugs
There are the following known bugs in this release:
Nr
Name
5635 Wrong basic clock
frequence with the CAN
configuration over chip
parameter
5674 [PreReleases 1.8.1 only]
Usage of VLAN
functionality limited
5676 [CAM] Video blocks
clearly smaller than 60
seconds.
Copyright Telemotive AG, alle Rechte vorbehalten.
The conversion or sorted
download inserts the markers on
the wrong place in the trace files.
Wrong time in data is shown after
client conversion to .BLF.
Trigger event "CAN receive"
wrong for 16 Bit signals.
If a VLAN ID is provided for one
of two Ethernet channels which
are in the same subnet, the
logger crashes.
With very short start and stop
sessions, no data is recorded.
If the voltage at the logger fell
below a value of 5V, no clean
reset was performed by the
logger. This could lead to the
behaviour, that the data on
several vehicle interfaces was not
recorded anymore and that the
logger did not change to sleep
mode.
Multi threading problem - two
threads have access on the same
gz-file.
Description
The results are wrong
parameters. Please configure it
with the RadioButton "baud rate".
Currently the VLAN functionality
is only usable at the Ethernet
1GBit/s port at the front.
Bug occurs with AXIS cameras
and video server. Video frames
will be lost at the compression.
Bug will be reported to AXIS.
[Ticket = '2013041985000024']
[Ticket = '2013041785000046']
[Ticket = '2013041985000042;
2013010885000096']
[Ticket = '2013042385000052']
[Ticket = '2013041985000033']
[Ticket = '2013022685000014']
To minimize the problems with
low voltage (e.g. during motor
start), it is recommended to use a
cable with a cross section >
2.5qmm for power supply.
[Ticket = '2013052185000072']
Comment
don't work: Logger IP address
with activated VLAN = same IP
address without VLAN - Logger
IP address with activated VLAN in
the same subnet as the address
without VLAN