Herunterladen Diese Seite drucken

Telemotive AG blue PiraT2 Bedienungsanleitung Seite 20

Vorschau ausblenden Andere Handbücher für blue PiraT2:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5271 [PreReleases 1.8.1 only]
An I2C error caused
wrong EEPROM data
5275 Line breaks in error
description
5288 Inclusion of time zone
information
5293 [PreReleases 1.8.1 only]
Data overview shows
wrong time stamps
5311 BusSpec.xml parameters
are set wrong or not at all
5326 Stand by power
consumption too high
5331 Standby power
consumption too high
5337 No LIN padding bytes
filter
5348 LIN messages are not
recorded.
5389 No error message when
loading incompatible
offline configurations
5436 Setting "End time of data
block" was shown wrong
5514 CAN chip parameters
can not be set greater 9.
5532 [PreReleases 1.8.1 only]
Errors during conversion
into BLF format
5536 [PreReleases 1.8.1 only]
FlexRay conversion
errors with CANoe asc
format
Seite 20 von 22
blue PiraT2 Release Notes
Firmware/Client V1.8.1, Datum: 25.06.2013
Caused by an I2C bus error,
wrong EEPROM logger data
(date, time, firmware,
hardware...) are shown. The bug
was fixed.
For more increased usability,
automatic line breaks were
implemented in the input fields of
the bug reporter.
Time zone information are now
included within the XTMT file.
The client data overview shows
the wrong timestamp. The PC's
timestamp is shown instead of
the logger's timestamp.
Some BusSpec.xml parameters
(e. g. serial or protocol
parameters) are set wrong or not
at all by the client.
The LIN Tranceivers could not
enter the sleep mode. This
caused a general increased stand
by current.
The low speed CAN controllers
could not enter the sleep mode.
This caused a general increased
stand by current.
The padding byte filter doesn't
work during LIN channel
conversion.
LIN messages are not or not
correct recorded.
The transferring of incompatible
offline configurations was aborted
without user information. An error
message was implemented, to
update the logger firmware.
The already done "end time of
data block" setting (in circular
buffer mode settings) was shown
incorrect after reopening the
configuration.
The CAN chip parameters for
BTR0 and BTR1 can not be set
greater than 9.
BLF data converted via the client
can not be displayed in CANoe
without fault.
After client conversion of FlexRay
data into CANoe asc format,
CANoe 8.0 does not show all
messages.
Copyright Telemotive AG, alle Rechte vorbehalten.
[Ticket = '2013021585000026;
2013020485000047']
[Ticket = '2013021485000037']
[Ticket = '2013012185000089']
[Ticket = '2013021985000055']
[Ticket = '2012112185000017']
[Ticket = '2012112185000017']
[Ticket = '2013021585000044;
2013051585000084']
[Ticket = '2012121985000083']
[Ticket = '2013041785000108']

Werbung

loading

Verwandte Produkte für Telemotive AG blue PiraT2