Herunterladen Diese Seite drucken

S+S REGELTECHNIK THERMASGARD TM43 Bedienungs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für THERMASGARD TM43:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 3
D G U F r
THERMASGARD
® 
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Tauch- ⁄ Einschraub- ⁄ Kanal-Temperaturmessumformer,
kalibrierfähig, mit Mehrbereichsumschaltung
und aktivem Ausgang (Automatic Output Switching)
G U
Operating Instructions, Mounting & Installation
Immersion ⁄ screw-in ⁄ duct temperature measuring transducer,
calibratable, with multi-range switching
and active output (Automatic Output Switching)
F
Notice d'instruction
Convertisseur de température à immerger ⁄ à visser ⁄ en gaine,
étalonnable, avec commutation multi-gamme
et sortie active (Automatic Output Switching)
r
Руководство по монтажу и обслуживанию
Погружной ⁄ ввинчиваемый ⁄ канальный преобразователь температуры,
калибруемый, с переключением между несколькими диапазонами
и активным выходом (Automatic Output Switching)
Automatische Erkennung und Umschaltung
auf Normsignal 0...10 V oder 4...20 mA
Automatic detection and switching
to standard signal 0...10 V or 4...20 mA
A O S - P A T E N T E D
AU T OM AT IC OU T P U T S W I T CHIN G
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
6000-3070-0000-2XX 30700-2024 V200 06 ⁄ 2023
TM 43
TM 65
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
TM 43
(IP 54)
TM 65
(IP 67)
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Werbung

loading

Inhaltszusammenfassung für S+S REGELTECHNIK THERMASGARD TM43

  • Seite 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄...
  • Seite 2 D G U F r TM 43 THERMASGARD ®  TM 65 THERMASGARD ®  TM xx TM xx Maßzeichnung Dimensional drawing [inch] Dimensional drawing Plan coté Габаритный чертеж [mm] 1.93 1.93 2.52 2.52 M16x1.5 M16x1.5 M16x1.5 M16x1.5 ø 0.24 ø 0.24 ø...
  • Seite 3 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Patentiertes Qualitätsprodukt (Patent-Nr. DE 10 2012 017 500.0 und DE 10 2015 015 941 B4) ® Kalibrierfähiger Temperaturmessumformer THERMASGARD TM 43 / TM 65, mit acht umschaltbaren Messbereichen (max. –20...+150 °C), aktivem Ausgang, geradem Schutzrohr, Gehäuse aus schlagfestem Kunststoff mit Schnappdeckel (IP 54) / mit Schnellverschluss schrauben (IP 67), wahl weise mit ⁄...
  • Seite 4 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Messbereich [ °C ] Messbereich [ °F ] Displayanzeige (einstellbar) (einstellbar) (umstellbar) – 20...+ 150 °C – 4...+ 302 °F Imperial [°F] – 50... + 50 °C – 58...+ 122 °F SI (default) [°C] –...
  • Seite 5 Temperaturtabellen für Messumformer mit aktivem Ausgang Rev. Data-V20 0...+100 °C –20...+80 °C 0...+50 °C 0...+40 °C MB: +32...+212 °F –4...+176 °F MB: +32...+122 °F MB: +32...+104 °F °C °F °C °F °C °F °C °F [mA] [mA] [mA] [mA]  0  32 –...
  • Seite 6 Temperatur-Messumformer mit aktivem Ausgang Rev. Data-V20 Platine TM xx Anzeige und Eigendiagnostik DIP-Schalter THERMASGARD ® Messumformer mit Display interner Sensor 1 2 3 4 Status- Temperatur Display- [°C] stecker min. max. ±10K Offset interner passiver Temperatur Sensor [°F] (optional) Fühlerbruch Fühlerkurzschluss Automatic Output Switching Anzeige im Display...
  • Seite 7 Temperatur-Messumformer mit aktivem Ausgang Rev. Data-V20 2-Leiter- 3-Leiter- TM xx - I TM xx - A Anschluss Anschluss (AOS) +UB 24V DC +UB 24V AC/DC Ausgang Temp. 4...20mA Ausgang Temp. 0-10V / 4...20mA –UB GND (optional für –UB GND Hintergrundbeleuchtung) 2-Leiter-Anschluss für Geräte ohne ⁄...
  • Seite 8 Temperatur-Messumformer mit aktivem Ausgang Rev. Data-V20 Bürdendiagramm Abhängigkeit Ausgangsspannung TM xx - A TM xx - I vom Ausgangsstrom Bürdendiagramm (AOS-I) (2-Leiter-I) 4...20mA 4...20mA [ mA ] zulässiger Bereich [ V ] 450 500 Abhängigkeit Ausgangsstrom TM xx - A von Ausgangsspannung (AOS-U) 0 -10 V...
  • Seite 9 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. technischen Parameter der Thermometer mit den realen Einsatzbe- Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von dingungen zu erfolgen, insbesondere: der Gewährleistung und Haftung ausgeschlossen.
  • Seite 10 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Patented quality product (patent no. DE 10 2012 017 500.0 and DE 10 2015 015 941 B4) ® Calibratable temperature measuring transducer THERMASGARD TM 43 / TM 65, with eight switchable measuring ranges (max. –20...+150 °C / –4...+302 °F), active output, straight protective tube, housing made from impact-resistant plastic with snap-on lid (IP 54) / with quick-locking screws (IP 67), optionally with ⁄...
  • Seite 11 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Measuring ranges [ °C ] Measuring ranges [ °F ] Readout in the display (adjustable) (adjustable) (switchable) – 20...+ 150 °C – 4...+ 302 °F Imperial [°F] – 50... + 50 °C –...
  • Seite 12 Temperature tables for measuring transducers with active output Rev. Data-V20 0...+100 °C –20...+80 °C 0...+50 °C 0...+40 °C MR: +32...+212 °F –4...+176 °F MR: +32...+122 °F MR: +32...+104 °F °C °F °C °F °C °F °C °F [mA] [mA] [mA] [mA]  0  32...
  • Seite 13 Measuring transducers with active output Rev. Data-V20 Circuit board TM xx Display and internal diagnostics DIP switches THERMASGARD ® Measuring transducer with display internal sensor 1 2 3 4 Status Temperature Display [°C] connector min. max. ±10K Offset internal passive Temperature sensor [°F]...
  • Seite 14 Measuring transducers with active output Rev. Data-V20 2-wire 3-wire TM xx - I TM xx - A connection connection (AOS) +UB 24V DC +UB 24V AC/DC Output Temp. 4...20mA Output Temp. 0-10V / 4...20mA –UB GND (optional for –UB GND backlighting) 2-wire connection for devices with ⁄...
  • Seite 15 Measuring transducers, calibrateable, with active output Rev. Data-V20 Working resistance diagram Dependency of output voltage TM xx - A TM xx - I on output current Load resistance diagram (AOS-I) (2-wire-I) 4...20mA 4...20mA [ mA ] Admissible range [ V ] 450 500 Dependency of output current TM xx - A...
  • Seite 16 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical only be connected to safety extra-low voltage. Consequential damages parameters comply with the actual conditions at the place of utilization, caused by a fault in this device are excluded from warranty or liability.
  • Seite 17 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Produit de qualité breveté (n° de brevet DE 10 2012 017 500.0 et DE 10 2015 015 941 B4) Convertisseur de température étalonnable THERMASGARD ® TM 43 / TM 65, avec huit plages de mesure commutables (max. –20...+150 °C), sortie active, tube de protection droit, boîtier en matière plastique résistante aux chocs avec couvercle emboîté...
  • Seite 18 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Plages de mesure [ °C ] Plages de mesure [ °F ] Affichage de l'écran (réglables) (réglables) (commutable) – 20...+ 150 °C – 4...+ 302 °F Impérial [°F] – 50... + 50 °C –...
  • Seite 19 Tableaux de température pour convertisseur de mesure avec sortie active Rev. Data-V20 plage de mesure : plage de mesure : plage de mesure : plage de mesure : 0...+100 °C –20...+80 °C 0...+50 °C 0...+40 °C +32...+212 °F –4...+176 °F +32...+122 °F +32...+104 °F °C...
  • Seite 20 Convertisseur de mesure avec sortie active Rev. Data-V20 Carte de circuit imprimé TM xx Affichage et propre diagnostic DIP switches THERMASGARD ® Convertisseur de mesure avec écran internal sensor 1 2 3 4 Status Température Display [°C] connector min. max. ±10K Offset internal passive...
  • Seite 21 Convertisseur de mesure avec sortie active Rev. Data-V20 Raccordement Raccordement TM xx - I TM xx - A 2 fils* 3 fils (AOS) +UB 24V DC +UB 24V AC/DC Output Temp. 4...20mA Output Temp. 0-10V / 4...20mA –UB GND (optional for –UB GND backlighting) Raccordement 2 fils pour appareils...
  • Seite 22 Convertisseur de mesure étalonnable avec sortie active Rev. Data-V20 Diagramme de charge Tension de sortie indépendante TM xx - A TM xx - I du courant de sortie Load resistance diagram (AOS-I) (2 fils-I) 4...20mA 4...20mA [ mA ] Admissible range [ V ] 450 500...
  • Seite 23 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Veillez Effectuer l’installation en respectant la conformité des paramètres à ne brancher l’appareil que sur un réseau de très basse tension de sécurité. techniques correspondants des thermomètres aux conditions d’utilisation Nous déclinons toute responsabilité...
  • Seite 24 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Запатентованный высококачественный прибор (патент № DE 10 2012 017 500.0 и DE 10 2015 015 941 B4) Калибруемый измерительный преобразователь температуры THERMASGARD ® TM 43 / TM 65, с восемью переключаемыми диапазонами измерения...
  • Seite 25 THERMASGARD ® TM 43 ⁄ TM 65 Rev. Data-V20 Диапазоны измерения [ °F ] Диапазоны измерения [°C] Индикация на дисплее (настраиваемые) ( настраиваемые ) (переключаемый) – 20...+ 150 °C – 4...+ 302 °F Английская система мер [°F] – 50... + 50 °C –...
  • Seite 26 Таблицы температур для преобразователи измерительные с активным выходом Rev. Data-V20 Диап.: 0...+100 °C Диап.: –20...+80 °C Диап.: 0...+50 °C Диап.: 0...+40 °C Диап.: +32...+212 °F Диап.: –4...+176 °F Диап.: +32...+122 °F Диап.: +32...+104 °F °C °F °C °F °C °F °C °F [mA]...
  • Seite 27 Преобразователи измерительные с активным выходом Rev. Data-V20 Платы TM xx Индикация и самодиагностика DIP switches THERMASGARD ® Измерительный преобразователь с дисплеем internal sensor 1 2 3 4 Status Температура Display [°C] connector min. max. ±10K Offset internal passive Температура sensor [°F] (optional) Обрыв...
  • Seite 28 Преобразователи измерительные с активным выходом Rev. Data-V20 Двухпроводное Трехпроводное TM xx - I TM xx - A подключение подключение (AOS) +UB 24V DC +UB 24V AC/DC Output Temp. 4...20mA Output Temp. 0-10V / 4...20mA –UB GND (optional for –UB GND backlighting) двухпроводное...
  • Seite 29 Преобразователи измерительные, калибруемые, с активным выходом Rev. Data-V20 Нагрузочная диаграмма Зависимость выходного напряжения TM xx - A TM xx - I от выходного тока Load resistance diagram (AOS-I) (Двухпроводное 4...20 мA подключение-I) 4...20 мA [ мA ] Admissible range [ B ] 450 500 Зависимость...
  • Seite 30 Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подклю- Монтаж следует осуществлять с учетом соответствия прилагаемых чение должно осуществляться исключительно к безопасно малому технических параметров термометра реальным условиям эксплуатации, напряжению. Повреждения приборов вследствие несоблюдения упомя- в особенности: нутых...
  • Seite 31 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Seite 32 D G U F r TH - 08 THERMASGARD ®  TH 08 - ms ⁄ xx TH 08 - VA ⁄ xx TH 08 - VA ⁄ xx ⁄ 90 Maßzeichnung Maßzeichnung Maßzeichnung Dimensional drawing Dimensional drawing Dimensional drawing Plan coté Plan coté...

Diese Anleitung auch für:

Thermasgard tm65