Product Information / Produktinformation A6125
Bearing Vibration Monitor
1.6.6 Environmental conditions
Application class
Ambient temperature
Reference temperature
Nominal use range
Storage, transport temperature
Operating altitude
Relative humidity
Vibration
Path
Acceleration
Shock
Enclosure protection class
EMC immunity
Allowed degree of pollution
Enviromental Area
1.6.7 Mechanical structure
PCB
Width
Plug connector
Front element
2 LEDs green
2 LEDs red
2 SMB socket connectors
1 mini DIN round socket connector RS 232 for connecting a laptop / computer
Weight
KTF in accordance with DIN 40040
+25°C
0 ... +45°C (CSA
requirement and recommended range
max. range −10°C ... +65°C (not CSA conform)
−30 ... +85°C
up to 2000m above sea level
≤ 95
non condensing
%
In accordance with IEC−68 − 2 Part 6
0.15 mm at 10 ... 55 Hz
2
19.6 mm/s
at 55 ... 150 Hz
In accordance with IEC−68 − 2 Part 29
Peak acceleration value 98 m/s
Nominal duration of shock 15 ms
IP 00, open design in accordance with DIN 40050
In accordance with EN 50 081−1 / EN 50 082−2
satisfied
Category 2 (According to IEC 61010−1)
Indoor use only
Euro format (100 mm x 160 mm) in accordance with
DIN 41494
6 TE (approximately 30 mm)
DIN 41612, form F 48 M
Channel Clear channel 1 / 2
Alarms channels 1 / 2
For sensor channel 1 / 2
(for configuration and visualization purposes)
Approximately 320 g without packaging,
approximately 450 g with standard packaging