Product Information / Produktinformation A6125
Bearing Vibration Monitor
Signal outputs EO 1 / EO 2
d14 / d16
Voltage outputs 0...10V proportional to the bearing vibration, measuring range and signal
evaluation according to the characteristical variables channel 1 (EO 1) andchannel 2 (EO 2).
Open circuit and short circuit proof, non reactive.
Nominal range
Resolution
Per. load resistance
Internal resistance
Signal inputs EI1 / EI2
Inputs for single−channel measurement values 0 ... +10 V for connection with EO outputs
(not relevant for MMS 6125).
Voltage input EI1 / EI2
Nominal voltage range
Resolution
Internal resistance
Signal input KEY
The key pulse is required for internal RPM determination for checking the measurements in
the measured value analysis.
Signal input KEY (N)
Signal level
Input resistance
1.6.2 Channel monitoring
Supervision function
permanent supervision
of the measuring chains (sensors) by supervising the input signal levels on short−circuit
System voltages
μP function (watchdog)
Configuration & setting
parameters
External disable signal
0 ... +10 V DC
8−bit
> 10 kΩ
Approximately 50 Ω
b14 / b16
0 ... +10 V DC
10−bit
> 100 kΩ
d22
24 V logic,: LOW = 0 ... 3 V; HIGH = 13 ... 48 V
> 10 kΩ
and cable breaks
Voltage − OK
WD − OK
C&P − OK
ES