Herunterladen Diese Seite drucken

Zodiac ei Serie Montage- Und Gebrauchsanleitung Seite 29

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 50
(1)
(2)
Polaris EOS / Jandy Aqualink Controllers
Green wire (0V) on the '0V' terminal of the Ei
Red wire (+V) on the 'POS' terminal of the Ei
Yellow/white wire (B) on the 'B' terminal of the Ei
Black wire (A) on the 'A' terminal of the Ei
5.4 Checking wiring and connections
Once the connection between the external timer/controller and the Ei chlorinator is established, it
must be tested.
1. Switch on the external controller, then the Zodiac Ei.
2. If the connection is successful, a 'T' icon will be displayed in the upper right hand corner of the LCD
screen after about 20 seconds.
3. If the connection failed, switch off the two appliances and proceed with another test (Steps1 and 2).
!
NOTE: For safety reasons, the Zodiac Ei switches automatically to stop ('OFF') when communication
between the chlorinator and the external timer/controller is lost.
30
5.3 Wiring to the external controller
!
IMPORTANT: The following instructions must be read together with the
installation guide supplied with the external timer/controller.
1. Remove the grey cover by exercising a pressure on each side as indicated then
by pulling it up (1).
2. Remove the small white plug located on the lower metal panel of the Ei
power pack (2).
3. Remove the 4 screws maintaining the dark grey cover of the Ei power pack (3).
(3)
4. Carefully open up the Ei control box cover then remove with care the
ribbon cable connecting the 2 electronic cards. Then retrieve the Ei
power pack cover (4).
5. Insert the external controller cable (a cable guide- not supplied- might be
required depending on the diameter used). Place a plastic clamp ring on
the external controller cable as indicated to avoid potential tearing (5).
6. Put the panel cover and the 4 screws back in place then the grey cover.
Green
terminal strip
Clamp ring
Depending on the external controller brand, proceed with the
following wiring for the cable to be connected to the green terminal
strip (5) of the Ei chlorinator:
(5)
Ribbon cable
(4)
Pentair Intellitouch Controllers
Green wire to the 'B' terminal of the Ei
Red wire to the 'POS' terminal of the Ei
Yellow wire to the 'A' terminal of the Ei
Black wire to the '0V' terminal of the Ei

Werbung

loading