4.4 Setting the timer
The Ei chlorinator is equipped with 2 timers that can be programmed so as to release chlorine during
time periods that are different from the fi ltration time, and this, up to twice per day.
Note that the timer periods must be included within the fi ltration periods (no chlorine will be released
when the fi ltration is not running).
!
IMPORTANT: The use of the programmer is MANDATORY if the Ei chlorinator is connected to a
permanent power supply.
Setting the timer:
1. When on the default LCD display press the
will appear briefl y, then the following will be displayed: 'TIMER 1 ON - - : - -'.
2. Press the
key to set the start-up hour (The
incrementation).
3. Press the
key to set the start-up minutes (The
incrementation).
4. Once the desired 'ON' time is set, press the
'TIMER 1 OFF - -: - -' will be displayed.
5. Repeat steps 2 and 3 to set the stop time.
6. If you need to set a different time period, press the
repeat steps 1 to 5 above (Once for the onset time and another time to set the stop time). If you do
not need to program another time setting, press the
NOTE: When an 'ON' start time is defi ned a default stop time is proposed. To defi ne the stop time of
your choice just press the
To clear the timers:
1. When on the default LCD display press the
TIMERS' message disappears.
2. Press the
key ; the 'TIMERS CLEARED' message will appear.
The Ei programming is now cleared.
3. Press the
key to return to the default LCD display.
4. If necessary re-programme the device (see Setting the timer).
key to go to 'TIMER 1' setting. An automatic message
key can be held down to accelerate
key in order to move on to the 'OFF' time setting:
!
NOTE:
NOTE: once the programming of a time setting has been
made, a small 'T' icon will be displayed in the upper right
corner of your LCD screen.
and
keys to set the time.
key. Wait until the 'PRESS OUTPUT TO CLEAR
key can be held down to accelerate
key again in order to switch to 'TIMER 2' and
key to return to the LCD default display.
EN
27

Werbung

loading