Easy Control
6.
Sensor installation
6.1.
Assembly of Temp/STL temperature sensor
1.
Drill a Ø 10 mm hole to allow the cable to he
threaded into the cabin in accordance with the
installation plan.
2.
Fit the power cable in a plastic sleeve.
3.
Connect the leads in accordance with the wiring
diagram.
'
See section 7.
4.
Push the electrical leads back into the wall
element until the plastic sleeve is level with the
end of the wiring insulation.
5.
Attach the housing components to each other
with fixing screws (3 x 8 mm).
Align the ventilation slot on the
temperature sensor vertically before
attaching.
Important: In infrared cabins, install the
sensors at the designated points only.
Temp/STL
Fit centrally to the wall element, above the stove
and 100 mm from the ceiling.
6.
Secure the attached housing with screws (3.4 x
13 mm).
50701116/10.05
Sensor plate
Sensor housing
Cable sleeve
Fixing screws
PAGE 27