Herunterladen Diese Seite drucken

Storch Scirocco 2000 Advanced Originalbetriebsanleitung Seite 56

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
The fan heater is equipped with an adjustment control for the power (1) and an adjust-
ment control for the integrated thermostat (2). The power controller (1) has four positions:
Item
Scirocco 2000 Advanced
0
Off
1
Fan function
2
1,000 W
3
2,000 W
The thermostat operating range is +5°C to +85°C. It starts the device at the selected
power if the temperature falls below the set temperature, which means that there is a
heating requirement.
Overheating protection
If the temperature in the heater becomes too high for any reason, the automatic tempera-
ture limit switches off the heating output. The fan continues to run in this case.
Allow the device to cool down.
5. Commissioning
Please screw in the handle at the top of the unit using the supplied bolts in the threaded
holes provided for this purpose.
Before starting up, make sure that the voltage matches the voltage specified on the type
plate.
Position the device on a stable surface at a minimum distance of 1 m from walls and wet
or flammable objects.
Plug in the power cord and set the thermostat adjustment control (2) to "MAX". The device
is switched on when you set the power adjustment control (1) to the desired position.
If you now turn down the thermostat, the device switches off when you set the current
room temperature. Based on this, now set the desired temperature.
To switch off the device set the power adjustment control (1) to 0 position.
6. Maintenance
Clean the exterior of the fan heater regularly as dust and dirt can cause a fire hazard.
Cleaning the heating element with compressed air. In case of severe soiling, remove the
top cover.
56
Scirocco 3000 Advanced
Off
Fan function
2,000 W
3,000 W
Translation of the original instruction