1 - GENERAL INFORMATION
This hood has been designed to be wall-mounted above a cooking hob. It can be
installed under a wall unit or directly onto a wall. It can work either by ducting system
(external discharge) or filter (internal recirculation). Before starting the installation,
consideration should be given to the difficulties to be found during installation.
The installation work must be undertaken by a qualified and competent person
in conformity to the rules concerning the evacuation of contaminated air. The
manufacturer disclaims all liability for any damage or injury caused as a result
of not following the instructions for installation contained in the following text.
2 - SAFETY WARNINGS
2.1 - When used in the extraction mode, the cooker hood ducting must not be connected to a flue which is
used for exhausting fumes from appliances supplied with energy other than electric, such as a central
heating flue or water heating flue.
2.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with the voltage on the
rating plate inside the hood.
2.3 - Connect the cooker hood to the mains via a bipolar switch which has 3mm clearance between the
contacts.
2.4 - The device does not require earthing, as it is double-insulated.
2.5 - When installed, the hood must be positioned at least 65 cm above the hotplate.
2.6 - Never do flambé cooking under this cooker hood.
2.7 - Never leave frying pans unattended during use as overheated fat and oil may catch fire.
2.8 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the mains supply.
2.9 - If the room where the cooker hood is to be used contains a fuel burning appliance such as a central
heating boiler then this must be of the room sealed or balanced flue type. If other types of flue or
appliance are fitted, ensure that there is an adequate supply of air into the room. When the cooker hood
is used in conjunction with appliances supplied with energy other than electric, the negative pressure in
the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker
hood.
2.10 -The appliance must be positioned so that the plug is accessible.
2.11 -If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer or its service agent.
3 - INSTALLATION
3.1 - Wall installation
The hood can be supplied with two different fixing kits:
a) screws, plugs and safety square.
b) screws, plugs and metal brackets.
Part 1 - INSTALLATION INSTRUCTIONS