Herunterladen Diese Seite drucken

Cola DOMUSFIRE C17 HR Installations-, Bedienungs- Und Wartungsanleitung Seite 55

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

The Figure opposite describes the meaning of the status
indicators in the left part of the display.
Activation of one of the segments on the display signals
activation of the corresponding device according to the
list opposite.
4.3 Lighting
4.3.1 Check before lighting
Before lighting the boiler:
- make sure to have read and understood the information given in the manual;
- follow the oral instructions on operation of the unit provided by the installer prior to use.
- the hopper must be filled with pellets;
- the combustion chamber must be clean;
- the brazier must be completely free, cleaned of any combustion residuals and correctly fitted in the brazier
holder;
- check hermetic closing of the ash box and fire door;
- check the connection of the power cable and switching to ON/1 of the switch located on the back of the boiler.
- check opening of the delivery and return shutoff valves as well as the water circuit pressure.
- At first startup, remove all the components that could burn (instructions/label) from the boiler firebox.
- Any lighting done after long idle periods requires the removal of any residual pellets that have remained
inside the hopper, in being damp fuel no longer suitable for combustion, and complete cleaning of the
combustion chamber.
4.3.2 Startup stage
To light the boiler, press the button 'P4' for 3 seconds: the message 'START' will appear on the display.
This stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters.
Alternatively the boiler can be lit by pressing the buttons P4 and P5 together for 3 seconds. The message
AWAITING REQUEST appears on the display. With this mode the boiler switches to standby status and carries out
the lighting-start stage only if a request for heat is recognised, e.g. to heat the water or for DHW (if available).
Dialogue box
Clock
Storage tank-Puffer H
Water temperature
External contact
Chrono
Heater
Auger
Fume extractor
DHW circuit activation
HEATING circuit activation
ALARM
0 temperature
2
Button 'P4'
55
DOMUSFIRE C17-C24 HR

Werbung

loading

Diese Anleitung auch für:

Domusfire c24 hr