OPTIONAL
SUPPLEMENTARY
HOPPER
In case of more than one heating unit in the same place, even fed with different fuels, as well as hoods with or
without exhaust fan, installation must be checked by a specialized technician, considering that the boiler has a fume
extractor installed on the lower fume manifold inside it.
Provide the appropriate air intakes for each of them according to the manufacturers' directions, in order to ensure the
simultaneous operation of all units in the heaviest operating conditions.
-The boiler must not be installed where there are heating units that draw combustion air from the room
in which they are installed, or from adjacent and adjoining rooms.
-Installation in places with danger of fire is forbidden.
46
BOILER
A = 500 mm
B = 500 mm
C = 500 mm
D = 1000 mm
L = 1350 mm
P = 700 mm
Antiwind
grille
Flue
Flue connection
Fume sampling point
for emissions check
Inspection door on
flue
Wall air inlet
min. 100 cm²
T union with
inspection cap