Herunterladen Diese Seite drucken

Adam Equipment AE 402 Bedienungsanleitung Seite 24

Anzeigegerät
Vorschau ausblenden Andere Handbücher für AE 402:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameter
Description
F1 Lo
Set Low limit.
F2 Hi
Set High limit.
F3 bEP
This parameter sets the
Beeper to off or on. If set to
on, the beeper can further
be set to sound when the
weighing result is within or
outside the check-weighing
limits.
F4 nCK
This
negative
function with ability to do
negative tare.
7.2
PERCENT WEIGHING
See section 6.7 and 6.8 for details of these special weighing modes.
• Press [Z/T] to enter a parameter. Use the [Unit/] key and [Pcs/] key to
set the values or just the [Pcs/] key to select the options.
• Press [Z/T] to confirm the change and then advance to the next parameter by
pressing the [Pcs/] key.
parameter
enables
check
weighing
ANIMAL WEIGHING
AND
Options
Use the [Unit/] key
and [Pcs/] key to set
the values of the lower
limit.
When set press the [Z/T]
key to store the value
and go to F2 Hi
Use the [Unit/] key
and [Pcs/] key to set
the values of the high
limit.
When set press the [Z/T]
key to store the value
and go to F3 bEP
bP oFF - Off
bP inL - Within limits
bP otL - Outside limits
(>20d)
on
oFF
© Adam Equipment Company 2010
Default
setting
000000
0000000
bP inL
on

Werbung