1.. General
1.1 Application
This operating instruction is valid for the jet pump and booster kit series EP and EPA.
Non-compliance with the operating instructions - in particular with the safety instructions - as well as non-manufacturer modification or use
of non-original spare parts will result in loss of guarantee coverage. The manufacturer accepts no liability for damage or injury resulting from
incorrect use of the equipment.
This product may also pass as any other electrical equipment in cause of lacking electrical supply. If you may get any damages thereby,
please calculate in accordance to the use an emergency power generator, a second pump and/ or a network independent alarm system. As the
manufacturer we will be after the buying at your disposal for near information. In cause of defects or damages please contact your retail
trader.
Manufacturer:
ZEHNDER Pumpen GmbH
Zwönitzer Straße 19
08344 Grünhain-Beierfeld
Product variations
Instruction last modified: December/2018
1.2 Queries and Ordering
For queries and orders please contact your authorised retail trader.
1.3 Technical data:
Typ:
Power (P
)
1
Voltage
Nominal current
Nominal speed
max. capacity
max. head
Outlet size
Inlet size
Sucking to max.
Cable length
Weight
The pumps at series EP and EPA are applicable to a liquid temperature of max. 40° C.
Materials:
Pump housing:
Stainless steel
Impeller:
Polyphenilenoxyd (PPO-GF)
Ejector:
Polyphenilenoxyd (PPO-GF)
Motor shaft:
Stainless steel
Screws:
Stainless steel
Seals:
NBR
Mechanical seal:
Carbon/ceramic/NBR/ stainless steel
Diaphragm vessel: Painted steel (EPA) stainless steel (EPA- E), powder coated steel with built-Butylmembran (EPA-P)
1.4 Areas of application
The pumps will be used to deliver clean water out of wells, creeks and tanks for irrigation, domestic water supply, etc. The pumps are
designed for pumping thin, clean, non-explosive liquids, not containing solid particles or fibres. The temperature of the pump liquid must not
exceed 40°C.
Sand and other abrasive parts may damage the seals or other parts of the pump (use a pre-filter).
EP 11-3
EPA 11-3
EPD 11-3
EP 15-3
EPA 15-3
EPD 15-3
EP 11-3
EPD 11-3
EPA 11-3
EPA 11-3E
ERA-P 11-3
600 Watt
230 V
50 Hz
2,9 A
2800 rpm
3200 l/h
43 m
G 1" FT
G 1" FT
8.5 m
1.5 m
10.5 / 15.5 kg
EPA 11-3E
EPA-P 11-3
EPA 15-3E
EPA-P 11-3
EP 15-3
EPD 15-3
EPA 15-3
EPA 15-3E
EPA-P 15-3
1000 Watt
230 V
50 Hz
4.4 A
2800 rpm
3800 l/h
46 m
G 1" FT
G 1" FT
8.5 m
1.5 m
11.5 / 16.5 kg