Possible problems / Corrective action
Possible problems
The burner does not light up
The burner does not burn smoothly or goes out
Unstable blowing flames
Large plume of flame on the burner surface
Flame at the injector
Burning leak around a union
Insufficient heat
Burning leak behind the adjustment knob
GB
Probable causes / Corrective action
- Poor gas supply
- Regulator not operating properly
- Pipe, valve, venturi tube or burner holes obstructed
- Check that gas is present
- Check the pipe connection
- Contact your servicing agent.
- New cartridge may contain air. Keep the stove running for a bit.
- Residual water due to washing the burner caps.
- Contact your servicing agent.
- The venturi is obstructed (possibly cobwebs)
- Contact your servicing agent.
- The cartridge is almost empty
- Change the cartridge
- Contact your servicing agent.
- Shut off the gas supply immediately
- Leaking union: tighten nuts or change pipe
- Contact your servicing agent.
- Injector or venturi tube obstructed
- Contact your servicing agent.
- Defective valve
- Shut down the stove
- Contact your servicing agent.