Installation Instructions S7-1413/Windows NT
4.6
Activating the SAPI-S7 Database
LDB or XDB
Format?
Activating the
Database in LDB
Format
Activating the
Database in XDB
Format
Palle,1413,W98,WNT
70
The way in which you activate a SAPI-S7 database depends on
whether the database was created in LDB or in XDB format .
A SAPI-S7 database created in the LDB format is activated in the
"S7 Protocol" tab (taskbar Start
Set PG/PC Interface
Parameter Assignment used "
"S7-Protocol" tab). Then continue as outlined in the table below:
Step
1
Select the check box "Activate S7" and click the left
mouse button. The "SAPI S7 Database" list box is
activated.
2
Enter a valid database in the "SAPI-S7 Database" list box.
3
Close the configuration program with OK.
A SAPI-S7 database created in the "XDB" format is activated in the
"STEP 7 Configuration" tab (taskbar Start
Set PG/PC Interface ). Then continue as outlined in the
Panel
table below:
Step
1
Enter the name of a valid database with the extension
".XDB" in the "Configuration file name" list box.
2
Close the configuration program with OK.
Settings
list box " Interface
Access Path
entry "CP1413"
Action
Settings
Action
Installationsanleitung S7-1413/Windows NT
Control Panel
Properties
Control
C79000-B8274-C383-02