Herunterladen Diese Seite drucken

HEYLO 1110599 Bedienungsanleitung Seite 18

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Display B
(ALARM)
The display B lights up red when a failure or an alarm message has been released.
(please also refer to the fault list / fault finding chapter 7)
Display C
(Display)
Display C will display the version number of the electronics software (such as 0100, for example)
for about 4 seconds when connected to power (connecting the plug).
For other displays see table:
Action
none
Actuate button 2 or 3
None
Actuate button 4
none
Display D
(RUN) (display is active when unit is operating only).
If the display is off, the unit is in break mode (air humidity set has been reached, for example). If the
display is flashing, the unit is in the defrosting phase or compressor delay after having been switched
on (takes up to 210 s.).
Display E
(FULL)
Display E lights up red when the condensate tank is full.
ALARM RESET - alarm is reset:
Set the operating switch of the machine "POWER" (1) to position "OFF", and subsequently press the
"HOUR" and "SET % +" (3) for 10 seconds - all alarms will be reset.
Error display (alarm) overview, see chapter 7
ATTENTION: Check whether the operational noise from the blower and compressor is correct
before leaving the unit unattended.
CAUTION: Check the condensation dryer for correct operation every day. Protect floor
against potentially draining water. Empty the condensate tank in regular intervals.
Putting the unit out of service
To switch the unit off, set the operating switch (1) to Off or 0. The display A and D goes off.
Read the operating hour meter after finishing the drying process and document the count, if
and when necessary.
Read the kW/h meter after finishing the drying process and document the count, if and when
necessary.
Subsequently the mains plug can be removed, and the unit can be transported away.
Condensate tank
When the condensate tank is full, the button „Full" € lights up on the display.
New the condensate tank has to be emptied. For this purpose open the service flap on the rear side.
Subsequently remove the tank and empty it.
All manuals and user guides at all-guides.com
Display
Meaning
rH xx
Display of actual air humidity
Set value of moisture control
Cont
Permanent dehumidification
rH xx
Hydrostat operation
Full
Condensate tank is full
Xxxx
Display of operating hours in h
Defr.
Automatic defrosting is active
18
EN

Werbung

loading

Diese Anleitung auch für:

Dt 760Dt 7501110583