Operating and display elements / explanation of other functions
Position
Description
"POWER" button
1
"SET -" button
2
"SET +" button
3
"HOURS" button
4
"PUMP" button
5
"POWER" display
A
"ALARM" display
B
Display: „Display"
C
"RUN" display
D
Display: „ FULL"
E
Button 1
"ON/OFF" - on / off switching function:
By pressing the "POWER" button, the unit is set from ON to OFF mode and vice versa.
Button 2/3
„HUMIDITY SET" - humidity setting:
Press the up or down arrow button in "SET %" to increase or decrease the required air humidity
setting.
When one of the two buttons are pressed for the first time the display changes from the reading mode
to the setting mode of air humidity, and when pressing the respective button a second time the air
humidity setting is either increased or decreased.
(CAUTION: The internal hygrostat fitted is suitable only for rough determination of the
operating parameters and not for a precise measurement of the room air humidity. Values may
have to be checked by externally calibrated measuring device. HEYLO shall not assume any
liability for damage caused by overdrying of materials)
Button 4
„HOUR COUNTER" - job hour counting function:
When pressing the "HOURS" button, the display reads the previous number of operating hours of the
compressor for some seconds.
When pressing the "RESET" button in off mode for four seconds, the job hour counter is set to 0.
„HOUR COUNTER" - total hour counting function:
When pressing button 4 (HOURS) + button 3 (SET), the display reads the previous number of total
operating hours of the compressor for some seconds.
Button 5
„PUMP" – Pump function
To activate the pumping function press the buttons 5 and 3 at the same time until the Tank FULL
display lights up. The display reads PUMP. The pump is active now; the display FULL flashes every
ten seconds.
When the (optional) condensate feed pump is connected, this can be controlled manually by pressing
button 5. This should be done for testing or disconnecting the unit.
Display A
(POWER)
The "POWER" display is green when the unit has been switched on.
All manuals and user guides at all-guides.com
Function
Start button (on/off)
Setting parameter (minus)
Setting parameter (plus)
Display of operating hours
Manual pumping with optional pump
Display of the operating status (on or off)
Fault display when an alarm is released
Display of the selected parameter and of the operating status
Display of operation or break times
Display of full condensate tank
17