Installation
Set up the device horizontally
 C
Observe the following conditions:
• Ensure that the connection to the power supply is at least 2 m from the edge of the pond.
• Place the device so that the filter housing is always below the water level.
• Position the device so that the nozzle insert is above the water level.
• Place the unit in the pond on horizontal, firm and sludge-free ground.
Hang up the device
 D
Observe the following conditions:
• Ensure that the connection to the power supply is at least 2 m from the edge of the pond.
• Place the device so that the filter housing is always below the water level.
• Only operate the device without water feature.
• Screw the two screws into the filter base and hang the device on the two screws with a cord.
Fasten the cord on the side of the pond.
Set-up fountain/feature
In order to adapt the water feature, the length and the vertical position of the nozzle pipe need
to be altered. The water flow rate can be regulated using the two flow-rate regulators on the
branch valve.
How to proceed:
 E
1. Set the nozzle pipe to the length required.
2. Loosen the union nut, align the nozzle pipe vertically and hand-tighten the union nut once
again.
Commissioning/start-up
NOTE
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical compo-
nents.
Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
 F
The viewing window shows that the UVC lamp in the device is working.